9 replacement of parts – Glow-worm Hideaway 80BF User Manual

Page 20

Advertising
background image

20

221763A

9 Replacement of Parts

9.8 Piezo Unit

Pull door forward at the top to disengage the studs and lift to
release from slots, see diagram 7.3.

Remove mains inlet connector by pulling downwards, see
diagram 8.1.

Gain access to inside of the control box by removing the
securing screw located at the top of control box and unhooking
at the bottom, see diagram 9.4.

Disconnect the ignition lead at the piezo unit.

Note: To ease the removal of the piezo unit it is advisable to
temporarily remove the boiler thermostat from the control box.

Depress the retaining tabs and remove the Piezo unit.

9.9 Ignition Lead

Gain access to the boiler as Section 8.1.

Disconnect the ignition lead at the piezo unit, see diagram 9.4
and section 9.8.

Disconnect the lead at the spark electrode, see diagram 9.2.

When reconnecting lead make sure that the clear end is fitted
to the spark electrode.

9.10 Electrical Control Box

Gain access to the boiler as Section 8.1.

Disconnect the mains inlet connector, see diagram 8.1.

Remove the thermostat phial by removing the retaining split pin
from the phial pocket and withdrawing the phial, see diagram
4.5.

Disconnect the gas valve plug from the valve, see diagram 9.1.

Pull the ignition lead off at the piezo unit, see diagram 9.4.

Remove the electrical control box cover securing screw and
unhook the cover at the side.

Remove the two screws and nuts to release the box from the
support bracket.

Refit the thermostat phial as Section 8.5.

Diagram 9.5

CONTROL BOX AND GAS VALVE WIRING

6284

CHASSIS
EARTH

230V~ 50Hz

MAINS SUPPLY

FUSED AT 3A

BLUE

BLACK

GREEN / YELLOW

BROWN

C

THERMOSTAT

GAS VALVE

N

E

N

L

VIEW OF PLUG
WHEN REMOVED

L

GREEN/
YELLOW

N/C

7995

ELECTRICAL
CONNECTORS

ELECTRICAL
CONTROL BOX
COVER

COVER
SECURING
SCREW (4)

ELECTRICAL
CONTROL BOX

THERMOSTAT
SECURING
SCREW (2)

THERMOSTAT
CONTROL KNOB

PIEZO
UNIT

HOOK

IGNITION LEAD
(BLACK END)

CUT-OUT FOR
CAPILLARY

SECURING SCREW

THERMOSTAT
AND CAPILLARY

Diagram 9.4

CONTROL BOX

Advertising