General data – Glow-worm Hideaway 80BF User Manual

Page 5

Advertising
background image

5

221763A

General Data

A

B

C

D

E

F

G

H

J

K

L

M

N

P

mm

387

171

558

294

363

533

3

300

445

121

156

664

292

398

in.

15

1

/

4

6

3

/

4

22

11

1

/

2

14

1

/

4

21

1

/

8

11

3

/

4

17

1

/

2

4

3

/

4

6

1

/

8

26

1

/

8

11

1

/

2

15

5

/

8

RANGE RATING

NOMINAL

kW

HEAT INPUT
(GROSS)

Btu/h

25.76

27.58

29.41

87,900

94,100 100,350

min

medium

max

BURNER

mbar

SETTING
PRESSURE

in.w.g

(HOT)

11.5

13.2

15.2

4.6

5.3

6.1

NOMINAL

kW

HEAT
OUTPUT

Btu/h

20.52

21.98

23.45

70,000

75,000

80,000

205749

INJECTOR

Important Notice

This boiler is for use only on G20 gas.

Wherever possible, all materials, appliances and components
to be used shall comply with the requirements of applicable
British Standards.

Where no British Standard exists, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.

1.1 Data

Weight of boiler

105.8kg (232lb)

Water content

8.64litre (1.9 gall)

Gas connection

Rc

1

/

2

1

/

2

inBSP

Water connection

Rc1 1 in BSP

Electrical supply

230V ~ 50Hz fused 3A

Burner

Aeromatic

All dimensions are given in millimetres (except as noted).

The Seasonal Efficiency Domestic Boilers UK (SEDBUK)
is 72.6%.

The value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

1.2 Range Rating

This boiler is range rated and may be adjusted to suit individual
system requirements.

The tables give the appropriate settings and ratings.

The boiler heat input is factory preset to its maximum rating.
This should be adjusted to suit individual system requirements.

The arrow indicator, from the loose items pack, should be stuck
on the data label to indicate the setting.

1.3 Sheet Metal Parts

WARNING. When installing or servicing this boiler, care should
be taken to avoid any possibility of personal injury when
handling sheet metal parts.

1.4 Statutory Requirements

The installation of this boiler must be carried out by a competent
person in accordance with the relevant requirements of the
current issue of:

Manufacturer’s instructions, supplied.

The Gas Safety (Installation and Use) Regulations, The Building
Regulations, Local Water Company Bye-laws, The Building
Standards (Scotland) Regulations (applicable in Scotland) Health
and Safety at Work Regulations, Control of Substances
Hazardous to Health, Electricity at Work Regulations and any
applicable local regulations.

Detailed recommendations are contained in the current issue of
the following British Standards and Codes of Practice,

BS6891, BS5440 Part 1 and 2, BS6798, BS5449, BS5546,
BS6700, BS7478, BS7593, BS7671.

Manufacturer’s instructions must not be taken as overriding
statutory requirements.

GENERAL DIMENSIONS - given in millimetres (Approx. inches)

Diagram 1.1

1071

Refer to BOILER CASING

HEIGHT diagram

M

D

C

C

L

A SPECIAL TOP CASING

TO SUIT 600mm (23

5/

8

in.)

WORKTOPS IS AVAILABLE

WATER CONNECTIONS

Rc1 (1in. B.S.P.T.)

WATER CONNECTIONS Rc1 reduced
with DISTRIBUTOR TUBE to
Rc

3/

4

(

3/

4

in. B.S.P.T.) (pumped return)

GAS CONNECTION

Rc

1/

2

(

1/

2

in. B.S.P.T.)

F(MIN.)

L

H

A

L

C

B

N

P

C

L

E

J

K

G(MIN.)

G(MIN.)

Advertising