7 gas, water and condensate connections – Glow-worm hxi and Gas Valve User Manual

Page 23

Advertising
background image

23

0020008153-05

INTERNAL SOIL
AND VENT STACK

BOILER

Ø22mm MIN.
NO RESTRICTION
ON LENGTH

EXTERNAL SOIL
AND VENT STACK

Ø22mm MIN.
NO RESTRICTION
ON LENGTH

BOILER

BOILER

Ø22mm MIN.

EXTERNAL LENGTH
OF PIPE 3M MAX.

OPEN END OF PIPE
DIRECT INTO GULLEY
BELOW GROUND BUT
ABOVE WATER LEVEL

Ø22mm MIN.
NO RESTRICTION
ON LENGTH

BOILER

SINK
(CONSTITUTES
AIR BREAK)

BOILER

Ø22mm MIN.
NO RESTRICTION
ON LENGTH

SINK

OPEN END OF PIPE DIRECT INTO
GULLEY BELOW GROUND LEVEL
BUT ABOVE WATER LEVEL.

Ø22mm MIN.
TERMINATION FROM APPLIANCE.

EXTERNAL LENGTH OF PIPE
3M MAX.

25mm MIN.

SEAL

BOTTOM OF
TUBE SEALED

Ø100mm
PLASTIC TUBE

300mm
MIN.

GROUND
(either/or)

500mm MIN.

HOLE DEPTH
400mm MIN.

LIMESTONE CHIPPINGS

2 ROWS OF 3 x 12mm HOLES AT
25mm CENTRES 50mm FROM
BOTTOM OF TUBE. HOLES TO
FACE AWAY FROM HOUSE.

External Soil and Vent Pipe or Rainwater Pipe

Internal Soil and Vent Pipe

External Termination into Soakaway

Internal Termination Downstream of
Sink Waste

Internal Termination into Combined Sink Waste

External Termination to a Gulley or Hopper

*

EXTERNAL
MAX. 3M

*NOTE: FOR EXTENDED
PIPE RUNS 32mm DIA.
PIPE SHOULD BE USED.

7 Gas, Water and Condensate Connections

13000

Diagram 7.3