8 servicing – Glow-worm Inset BBU50 User Manual

Page 19

Advertising
background image

19

221723B

Diagram 8.2

6205

CONTROL BOX

GAS
CONTROL
VALVE

COMBUSTION
CHAMBER

GAS SERVICE
COCK

FIRE FRONT
GAS SERVICE
COCK

MAINS
ELECTRICAL
PLUG

FLOOR PROTECTION
PLATE

COMBUSTION CHAMBER
SECURING SCREWS (4)

GAS MANIFOLD
SECURING SCREW

COMBUSTION
CHAMBER
FRONT COVER

UNION

BURNER SECURING
SCREWS (3)

8 Servicing

8.3 Controls Assembly and Burner.

Disconnect the union at the gas service cock, see diagram 8.2.

Remove the thermostat phial and overheat cut-off device phial
if fitted (sealed systems only), from the phial pockets, unclip the
capillary tubes, see diagram 5.4.

Disconnect the mains electrical plug from the control box, see
diagram 8.2.

Remove the four combustion chamber securing screws.

Remove the gas manifold securing screw and slide the control/
burner assembly forwards to remove, see diagram 8.2.

8.4 Burner

Disconnect the pilot tube nut and the thermocouple nut from the
gas control valve, see diagram 8.3.

Disconnect the ignition lead at the electrode.

Remove the extended screws which locate the gas manifold to
burner, see diagram 8.3.

The control box and gas control valve can now be lifted clear of
the burner.

Clean the burner as necessary, do not use a brush with metallic
bristles.

8.5 Lint Arrester

Remove the four securing screws to disengage the two lint
arresters, see diagram 8.4.

Clean the lint arresters as required.

Diagram 8.1

6300

FILTER

SENSING TUBE
FITTING

SECURING
SCREW

SENSING TUBE

“O” RINGS

SENSING TUBE

DRAUGHT
DIVERTER

FLUE
BLOCKAGE
SAFETY DEVICE

TUBING
NUT

RETAINING NUT

Advertising