3 water systems – Glow-worm Ultimate 50FF User Manual

Page 10

Advertising
background image

10

2000225232B

3 Water Systems

Diagram 3.2

Diagram 3.3

0090M

1m MIN.
27m Max.

PUMP

HEATING
SYSTEM

INDIRECT
CYLINDER
(Shown with
recommended
thermostat and valve).

22mm VENT

15mm COLD FEED

REFER TO BS 5546

28mm

VIEWED
FROM
FRONT

6455

FEED AND
EXPANSION
CISTERN

22mm VENT
(MIN.)

15mm (MINIMUM)
COLD FEED

OPEN VENTED FULLY PUMPED WATER SYSTEM
RECOMMENDED RELATIONSHIP BETWEEN
PUMP COLD FEED AND VENT

450mm
MIN.
HEIGHT

1150mm
MIN.

RETURN

FLOW

CYLINDER

PUMP

HEATING

150mm
MAX.

BOILER

IF REQUIRED
15mm (MINIMUM)
BY-PASS WITH
LOCKSHIELD VALVE

FLOW

RET.

There must always
be a cold water path
to the return
connection
of the boiler.

PUMPED

RETURN

PUMPED

FLOW

4124

Diagram 3.4

1metre Min.

27 metres

Max.

22mm VENT & 15mm COLD FEED
TO BE FITTED IN ACCORDANCE
WITH BS 5449

INDIRECT
CYLINDER

ALTERNATIVE
SYSTEM
CONTROL
VALVES

HEATING
SYSTEM

PUMP

FULLY PUMPED CIRCULATION
SYSTEM (DIAGRAMMATIC)

6461

IF REQUIRED
BYPASS 15mm
MIN WITH
LOCKSHIELD
VALVE

22mm
PIPE

RETURN

FLOW

4107

1metre Min.

27 metres

Max.

22mm FOR COMBINED FEED & VENT
TO BE FITTED IN ACCORDANCE
WITH BS 5449

INDIRECT
CYLINDER

ALTERNATIVE
SYSTEM
CONTROL
VALVES

HEATING
SYSTEM

PUMP

FULLY PUMPED CIRCULATION
BYPASS (DIAGRAMMATIC)

6456

IF REQUIRED
BYPASS 15mm
MIN WITH
LOCKSHIELD
VALVE