Instructions for use – Glow-worm Ultimate 50FF User Manual

Page 3

Advertising
background image

3

2000225232B

4140

CONTROLS COVER

Instructions for Use

Introduction

WARNING: It is important that the case (not the controls tray)
is not disturbed or removed other than for servicing by a
competent person.

The user shall not interfere with or adjust sealed parts.

Please read these instructions and follow them carefully for the
safe and economical use of your boiler.

The Ultimate FF series are fanned flue boilers designed to
provide central heating and indirect domestic hot water.

The boiler is fully automatic in operation having only one user
control, the control thermostat.

IMPORTANT NOTICE

If your boiler has been converted to use L.P.G. Propane the
following applies:

NOTE: Propane cylinders are under pressure and should never
be stored or used indoors residentially.

They should only be kept outside.

Under no circumstances should L.P.G. Propane cylinders be
fitted or stored in basement areas or boiler houses.

The Gas Safety (Installation and Use)
Regulations

In your interest and that of gas safety it is the law that ALL gas
appliances are installed by a competent person in accordance
with the above regulations.

Gas Leak or Fault

Turn off the gas emergency control valve immediately. Eliminate
all sources of ignition, i.e.smoking, blowlamps, hot air guns etc.
Do not operate electrical lights or switches either on or off. Open
all doors and windows,ventilate the area.

Electrical Supply Failure

Failure of the electrical supply will cause the burner to go out.
Should this occur, operation of the appliance will normally
resume after the electrical supply is restored.

If the boiler does not relight after an electrical supply failure the
overheat safety cutoff device may need resetting, remove the
controls cover and press the reset button, refer to diagram 1.

Overheat Safety Cutoff

If the overheat safety cutoff device operates on any other
occasion than an electrical supply failure, press the reset button
as in “Electrical Supply Failure”. If the overheat operates again,
turn the appliance off and contact your installation/servicing
company.

Maintenance

To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage,
but in general once a year should be enough.

If this appliance is installed in a rented property in the UK there
is a duty or care imposed on the owner of the property by the
current issue of The Gas Safety (Installation and Use)
Regulations, Section 35.

It is the law that any servicing is carried out by a competent
person
.

To obtain service, please call your installer or Glow-worm’s own
Service Organisation using the telephone number given on the
controls tray.

Please be advised that the ‘Benchmark’ logbook should be
completed by the installation engineer on completion of
commissioning and servicing.

All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boiler Logbook. You can check your installer is CORGI registered
by calling CORGI direct on :- 01256 372300.

Boiler Clearances

If fixtures are positioned close to the boiler space must be left
as shown in diagram 2. At least a minimum clearance of 500mm
must be left in front of the boiler to allow for servicing.

Boilers Installed in a Compartment or
Cupboard

If the boiler is installed in a compartment or cupboard do not
obstruct any ventilation openings.

Do not use the compartment or cupboard for storage.

Diagram 1

10264

DATA &
SERIAL
NUMBER
LABEL

RESET
BUTTON

VIEWING WINDOW

SETTING POINT

CONTROL
THERMOSTAT
KNOB

GAS SERVICE
COCK (Shown
Off)