ANY ASSISTANCE ?

- 17 -

9.2 Appliance fails to light

The LCD will display a flashing 'F' and

code number,

• To restart the boiler, press the reset

button, see chapter "How to use your

appliance ► Overview".

If any fault persists, and your appliance still

does not work, leave it switched off and

contact your competent person.

Like all condensing boilers

it will produce a plume of

condensation from the flue

terminal in cool weather.

This is due to the high

efficiency and hence low flue

gas temperature of the boiler.

It is normal and not a fault

indication.

10 Appliance safety devices

10.1 Boiler Shutdown

The boiler software is designed to

recognise the potential for an overheat

lockout and will shutdown before this

happens.

• To restart the boiler, press the reset

button, see chapter "How to use your

appliance ► Overview".

CODE DESCRIPTION

POSSIBLE CAUSES

F1

Boiler has attempted to

light 5 times and failed on

all occassions

Press the reset button.

If the fault persists, contact your Installation/Servicing

company or Glow-worm

F5

Overheat

Boiler has overheated - allow to cool then press reset button

If the boiler fails to resume normal

operation and all external controls are

calling for heat, then call your Installation/

Servicing company or Glow-worm service.

10.2 Protecting against frost

Appliance Protecion

In case of the risk of frost:

• Make sure that the electrical and gas

supply to the appliance is turned on.

• For an absence of several days, you

can leave the appliance to run normally.

The appliance has a built in frost

protection device that protects the boiler

from freezing. With the gas and electric

supplies ON and irrespective of any room

thermostat setting, the frost protection

device will operate the pump when the

temperature of the boiler water falls

below 8

O

C. A timer is used so that the

temperature can be checked periodically.

After 10 minutes the pump will be stopped

if the temperature is higher than 10

O

C or

has already reached 35

O

C. The burner

will activate if the boiler temperature

does not reach 10

O

C after 30 minutes or

at any time if the temperature drops to

5

O

C. The burner will switch off when the

temperature reaches 35

O

C.

The appliance always has frost protection

active when the power and gas supply are

on.