Golden Blount Precision Flame Burner User Manual

Page 12

Advertising
background image

12

PF-BARR-(20,24,30) LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing

property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lit by hand. When light-

ing the pilot, follow these instructions exactly.

B. BEFORE LIGHTING, smell all around the appliance area for

gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by hand,
don’t try to repair it; call a qualified service technician. Forced or
attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label.

2. Make sure the manual shutoff valve is fully open.

3. This gas log set is equipped with an ignition device (piezo)

which lights the pilot. If piezo ignitor does not light the pilot, refer
to Step 7.

4. Turn gas control knob clockwise

to the “OFF’’

position.

5. Wait ten (10) minutes to clear out any gas. Then smell for gas,

including near the floor. If you smell gas STOP! Follow “B” in the
safety information label. If you do not smell gas, go to the the
next step.

6. Find pliot – follow metal tube from gas control. The pilot is locat-

ed to the left of the gas control undr notch in metal chassis.

7. From OFF position, turn the gas control knob counterclock-

wise

to “Pilot” position. Push in and hold knob for

5 seconds.

RR (Remote Ready) Valve, Remote Control Option

The RR valve has an on/off solenoid internally located inside the valve
body. The optional RECAP-1 remote control can be added to allow the valve
to be operated by remote control.

8. With the control knob pushed in, repeatedly push the piezo

ignitor button until pilot is lit (or use a match to light pilot).

9. Continue pushing the control knob in for another 60 seconds

to prevent the flame detector from shutting off the gas while
the probe is warming up. Release the control knob.
• If the pilot will not stay lit after several tries, turn the gas

control knob to “OFF” and call your service technician or
gas supplier.

10. Turn gas control knob counterclockwise

to the

“ON” position. The main burner valve will open and the main
burner will ignite, provided the ON/AUX knob is in the ON
position.

11. Turn gas control knob counterclockwise

to the

“ON” position, with the ON/AUX knob in the “AUX” position
then remote control will operate the gas control valve and
cause the main burner valve to open and the main burner will
ignite. Flame height can be manually changed by turning the
HIGH/LOW control knob.

Ignitor Button

(Located left side appliance chassis)

TO TURN OFF GAS TO APPLIANCE

1. Turn control knob clockwise

to OFF position to

completely shut off the heater.

2. If applicable: Turn optional flame control option OFF prior to

turning control knob to OFF position.

Advertising