Hall Research VSM-I-A-16-16 User Manual

Page 38

Advertising
background image

36

Hall Research Technologies, Inc.

OK .................................................. if command completed successfully.
Error........................................................................... if command failed.

6.

To get the current subnet mask:

Command:

GNM <cr> stands for Get Net Mask.

Response:

255.255.255.0

7.

To set a subnet mask:

Command:

SNM255.255.255.0 <cr> stands for Set Net Mask.

Response:

OK .................................................. if command completed successfully.
Error........................................................................... if command failed.

8.

To get the current port number (this is the port to access the matrix):

Command:

GPN <cr> stands for Get Port Number.

Response:

1001

9.

To set a port number (IP port that controls the Matrix):

Command:

SPN1000 <cr> stands for Set Port Number.

Response:

OK .................................................. if command completed successfully.
Error........................................................................... if command failed.

10.

To get a device/host name:

Command:

GDN <cr> stands for Get Device Name.

Response:

xxxxxxxxxx

Note on Device Name

This is the host name assigned to the IP port; it is independent of the
name assigned to the matrix (NU command), though you can use the
same name if you wish!

11.

To set a device name:

Command:

SDNnew_name <cr> stands for Set Device Name.

Response:

OK .................................................. if command completed successfully.
Error........................................................................... if command failed.

12.

To reboot the system for the changes to take effect:

Advertising