Owner’s manual, Operating heater, Continued – Desa CGN10RLA User Manual

Page 11: Lighting instructions

Advertising
background image

11

104276

OWNER’S MANUAL

Control

Knobs

Burners

LOW

OFF

PILOT

HIGH

OFF

PILOT

OFF

Figure 17 - Burner Patterns

OPERATING
HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

MANUAL LIGHTING

PROCEDURE

TO SELECT

HEATING LEVEL

Pilot Burner

Thermocouple

Figure 16 - Pilot

LIGHTING

INSTRUCTIONS

Figure 15 - Control Knob In The OFF
Position

OFF

PILOT

IGNITOR

LOW

HIGH

Control Knob

Piezo Ignitor Button

1.

STOP! Read the safety information
page 10, column 3.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise
to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.

5.

Press in control knob, and turn coun-
terclockwise

to pilot position.

Keep control knob pressed for five
seconds.

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the front of burner. If needed, keep
pressing ignitor button until pilot lights.

Ignitor Electrode

WARNING: When running

heater, set control knob at LOW
or HIGH locked positions. Never
set control knob between locked
positions. Poor combustion and
higher levels of carbon monox-
ide may result.

1.

Slightly press in control knob and
turn counterclockwise

to the

LOW or HIGH positions.

IMPORTANT:

Release downward

pressure while turning control knob.
Control knob will lock at the desired
position.

1.

Remove front panel (see Figure 10,
page 8).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in,
strike match. Hold match to pilot
until pilot lights.

4.

Keep control knob pressed in for 10
seconds after pilot is lit. After 10 sec-
onds, release control knob.

5.

Replace front panel.

Shutting Off Heater

Turn control knob clockwise

to

the OFF position.

Shutting Off Burner Only
(pilot stays lit)

Turn control knob clockwise to the PI-
LOT position.

Note:

If pilot does not light, refer to

Troubleshooting, pages 13 through 15.
Also contact a qualified service person
or gas supplier for repairs. Until repairs
are made, light pilot with match, see
Manual Lighting Procedure
.

7.

Keep control knob pressed in for 10
seconds after lighting pilot. After 10
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.

CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Advertising