Installation, Continued – Desa YGF33PRB User Manual

Page 11

Advertising
background image

110148-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

11

11

1.

Frame in rough opening. Use dimensions shown in Figure 16
for the rough opening.

2.

If using blower, install wiring and properly ground the three-
prong, 120 volt electrical outlet in fireplace.

3.

Before replacing bottom of firebox, install duplex outlet to the
right support bracket in the bottom of firebox (see Figure 17).

4.

Route wires from electrical box through smallest hole in outer
casing using strain relief fitting provided (see Figure 17).

5.

Connect wires from the electrical box to duplex outlet. Match
wire colors to those indicated on duplex outlet. Be sure to con-
nect ground wire.

6.

Install shield to end of right support bracket and behind the
firebox wrapper with 2 screws provided (see Figure 18).

7.

Plug blower cord into duplex outlet.

Note:

On thermostat model

fireplaces, route power cord to the back of the fireplace to clear
thermostat valve.

8.

Replace bottom of firebox.

9.

Install gas piping to fireplace location. This installation includes
an approved flexible gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible gas line must be the
last item installed on the gas piping. See Installing Gas Piping
to Fireplace Location,
pages 12 and 13.

10. Carefully set fireplace in front of rough opening with back of

fireplace inside wall opening.

11. Attach flexible gas line to gas supply. See Connecting Fire-

place to Gas Supply, pages 13 and 14.

12. Plug electrical cord into electrical outlet installed in step 2.

13. Carefully insert fireplace into rough opening.

14. Attach fireplace to wall studs using nails or wood screws

through holes in nailing flange (see Figure 19).

15. Check all gas connections for leaks. See Checking Gas Con-

nections, pages 14 and 15.

16. Install brass trim after final finishing and/or painting of wall

(see Figure 7, page 8).

INSTALLATION

Continued

Blower

Support
Bracket

Cable from
Electrical
Source

Duplex
Outlet

Screw

Blower
Power
Cord

Strain
Relief
Fitting

Figure 17 - Connecting Duplex Outlet

35

1

/

2

"

17

3

/

4

"

33"

Figure 16 - Rough Opening for Installing in Wall

Figure 19 - Attaching Fireplace to Wall Studs (FPVF33PRA
Shown)

Nailing Flanges

Nails or
Wood
Screws

Shield

Screws

Support Bracket

Firebox
Wrapper

Power
Cord

Figure 18 - Attaching Fireplace to Wall Studs (FPVF33PRA
Shown)

INSTALLATION

Built-In Fireplace Installation (Cont.)

Advertising