4. PBX Systems

set these features exactly (and assigned to the right keys) so that the PBX
Integration Board and the Dialogic

®

Unified API can function correctly.

NEAX 2400 IMS and NEAX 2000 IVS, IVS2, and IPS Programming
Requirements

Transfers:

Allow the ports connected to the Dialogic

®

PBX Integration Board permission

to use the transfer key.

Message Waiting Indicator (MWI):

The default access dial strings for the Dialogic

®

PBX Integration Board are set

to **9 (on) and ##9 (off). If the PBX has not been set to use these dial strings,
you must:

• Use the d42_setparm( ) function to change dial string programmed in the

PBX to:

• D4BD_MSGACCESSON

• D4BD_MSGACCESSOFF

OR

• Change the PBX access dial string to **9 (on) or ##9 (off).

4.7.2. Using the Dialogic

®

PBX Integration Board

The Dialogic

®

PBX Integration Board can perform functions available to a

DTerm Series III telephone set (see

Figure 16

). The PBX Integration Board

can:

• transfer calls

• set the message waiting indicator

• read the LCD display

• read LCD indicators

• read the called/calling number ID

• press keys

151