Hatteland Display 19 inch - JH 19T14 MMC User Manual

Page 19

Advertising
background image

19

Serial Communication (SCOM) Interface

Communication Interface

IND100084-12

MCC Command

Syntax and Functionality

ACK Details and Values

Manual Phase Control

Note:

Dot clock (for RGB mode only)

Syntax : 07 FF 4D 43 43 03 23

85

xx yy

zz

Function Examples:
Example "3F" : 07 FF 4D 43 43 03 23

85

33 46

01

Query "?" : 07 FF 4D 43 43 02 24

85

3F

3B

Reset "R" : 07 FF 4D 43 43 02 24

85

52

28

Reset "r" : 07 FF 4D 43 43 02 24

85

52

08

Increase "+" : 07 FF 4D 43 43 02 24

85

2B

4F

Decrease "-" : 07 FF 4D 43 43 02 24

85

2D

4D

Where

xx

= "0" to "3"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "3" "F"

Image Horizontal Position

Syntax : 07 FF 4D 43 43 03 23

86

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

86

35 30

14

Query "?" : 07 FF 4D 43 43 02 24

86

3F

3A

Reset "R" : 07 FF 4D 43 43 02 24

86

52

27

Reset "r" : 07 FF 4D 43 43 02 24

86

72

07

Increase "+" : 07 FF 4D 43 43 02 24

86

2B

4E

Decrease "-" : 07 FF 4D 43 43 02 24

86

2D

4C

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default: "3" "2"

If DVI mode: "?"

Note: If Value > 100 then

Value=100

Image Vertical Position

Syntax : 07 FF 4D 43 43 03 23

87

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

87

35 30

13

Query "?" : 07 FF 4D 43 43 02 24

87

3F

39

Reset "R" : 07 FF 4D 43 43 02 24

87

52

26

Reset "r" : 07 FF 4D 43 43 02 24

87

72

06

Increase "+" : 07 FF 4D 43 43 02 24

87

2B

4D

Decrease "-" : 07 FF 4D 43 43 02 24

87

2D

4B

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default: "3" "2"

If DVI mode: "?"

Note: If Value > 100 then

Value=100

Sharpness

Note:

Not available on STD units.

Syntax : 07 FF 4D 43 43 03 23

8A

xx yy

zz

Function Examples:
Example "07" : 07 FF 4D 43 43 03 23

8A

30 37

0E

Query "?" : 07 FF 4D 43 43 02 24

8A

3F

36

Reset "R" : 07 FF 4D 43 43 02 24

8A

52

23

Reset "r" : 07 FF 4D 43 43 02 24

8A

72

03

Increase "+" : 07 FF 4D 43 43 02 24

8A

2B

4A

Decrease "-" : 07 FF 4D 43 43 02 24

8A

2D

48

Where

xx

= "0" to "F"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "0" "F"

Default: "0" "7"

Manual Frequency Control

Note:

PC mode only.

Syntax : 07 FF 4D 43 43 05 21

8B

vv ww xx yy

zz

Function Examples:
Example "0050" : 07 FF 4D 43 43 05 21

8B

30 30 35 30

AF

Query "?" : 07 FF 4D 43 43 02 24

8B

3F

35

Increase "+" : 07 FF 4D 43 43 02 24

8B

2B

49

Decrease "-" : 07 FF 4D 43 43 02 24

8B

2D

47

Where

vv

= "0" to "0"

Where

ww

= "0" to "0"

Where

xx

= "0" to "C"

Where

yy

= "0" to "E"

Where

zz

= Calculated Checksum

Max Range:

"0" "0" "0" "0" to "0" "0" "C" "E"

If wrong mode: "?"

Scaling Mode

Note:

Not available on STD units.

Syntax : 07 FF 4D 43 43 02 24

8C

xx

zz

Function Examples:
Example "2" : 07 FF 4D 43 43 02 24

8C

32

41

Query "?" : 07 FF 4D 43 43 02 24

8C

3F

34

Reset "R" : 07 FF 4D 43 43 02 24

8C

52

21

Reset "r" : 07 FF 4D 43 43 02 24

8C

72

01

Where

xx

= "0" to "4"

Where

zz

= Calculated Checksum

If wrong mode: "?"

Available functions:

"0" = 1:1

"1" = Fill Screen

"2" = Fill to Aspect Ratio

"3" = Anamorphic

"4" = Auto

OSD Horizontal Position

Syntax : 07 FF 4D 43 43 03 23

90

xx yy

zz

Function Examples:
Example "50" : 07 FF 4D 43 43 03 23

90

35 30

0A

Query "?" : 07 FF 4D 43 43 02 24

90

3F

30

Reset "R" : 07 FF 4D 43 43 02 24

90

52

1D

Reset "r" : 07 FF 4D 43 43 02 24

90

72

FD

Increase "+" : 07 FF 4D 43 43 02 24

90

2B

44

Decrease "-" : 07 FF 4D 43 43 02 24

90

2D

42

Where

xx

= "0" to "6"

Where

yy

= "0" to "F"

Where

zz

= Calculated Checksum

Max Range: "0" "0" to "6" "4"

Default: "6" "4"

Note: If Value > 100 then

Value=100.

If Value is not multiple by ten, it

change to less nearest multiple

value.

Advertising