www.desatech.com

122663-01D

5

CAUTION: Do not expose the

heater to the elements (such as

rain, etc.)

CAUTION: Wear gloves and

safety glasses for protection

during installation and main-

tenance.

Plan where to locate and frame fireplace.
Before installation consider the following:
1. Fireplace location must allow for wall and

ceiling clearances (see Installation Clear-
ances
).

2. Fireplace screen should not be exposed

to direct sunlight from windows or doors.

3. Unit can be wired for either 120/60 (15

amp circuit) or 240/60 (20 amp circuit).
A dedicated circuit should be provided
to avoid circuit breaker trips or blown
fuses.

Flush Installations are recommended where
living space is limited or at a premium. Since
space required to enclose fireplace would
be located beyond an outside wall, this in-
stallation would require additional planning
and construction. Check local codes for any
restrictions.
Projected Installations can extend any dis-
tance into room. A projection may be ideal for
a new addition on an existing, finished wall.
Corner Installations make use of space
that may not normally be used and provides
a wider and more efficient viewing angle and
heat distribution.
Internal Wall Installations provide a discrete
option for room separation and can also be an
ideal addition to an existing wall.

LOCATINg FIREPLACE

Continued

Figure 3 - Possible Installation Locations

Internal Wall

Installation

Full Projection

Installation

Flush

Installation

Corner

Installation

Facing Material May
Be Noncombustible
Wall Treatments or
Combustible Wood

Combustible Wood
Mantels and Trims
May Extend Above
Profile Shown when
Maintained within
30° Parameter
Shown

Framed
Material

Top of Cabinet

Note: All Mantel Clearances
are Measured from Top of
Fireplace Opening

30°

23"

12" Ref.

21"

4

1

/

2

"

1

1

/

2

"

15" Min.

17"

10

1

/

2

"

Figure 4 - Mantel Clearances

Top View of Fireplace

5"

3"

30°

1

3

/

4

" Max.

Minimum 10"

from Perpendicular

Side Wall

Edge of

Firebox

Opening

Combustible
Material Must
Not Overlap
Front Face

Safe Zone

Figure 5 - Mantel Side Clearances

INSTALLATION

INSTALLATION CLEARANCES

Minimum clearances to combustible construc-
tion are:
Top, Back and Sides of Recessed Cabinet 0" Min.
Drywall to Sides of Front Face

0" Min.

Framing at Nailing Flanges

0" Min.

Ceiling to Opening

36" Min.

Floor

0" Min.

Front

36" Min.

Perpendicular Side Wall

10" Min.

Mantel Clearances
For mantel clearances see Figures 4 and 5.