10

WARNING!

SAFETY FIRST!

Check for and turn off all power sources before connecting the trans-

mitter directly to otherwise power carrying cables.

Direct connection must NOT be to live 50/60 hertz power sources up to

240 VAC!! The power must be OFF!!

THE SURE-LOCK RECEIVER
(Figure 1-4)

1. ACTIVE FREQUENCIES: 8.1 kHz with Left-Right and depth displayed.
2. PASSIVE FREQUENCIES: 50-60 hertz without Left-Right depth.
3. DYNAMIC RANGE: 124 dB, typical.
4. DEPTH RANGE: Range to 20’ (240” or 610 cm) continuously displayed

(estimated depth). Metric units (cm) selectable per order. Automated “cal-
culated depth” function.

5. LEFT-RIGHT GUIDANCE: LCD indicators and audio prompts are pres-

ent.

6. AUDIO RESPONSE TYPE (Passive): Variable pitch.
7. GAIN ADJUSTMENT: Automatic.
8. LCD: Automatic backlighting. Indication of signal strength, battery level,

operating frequency mode, estimated and calculated depth, self-test status,
speaker volume, Left-Right arrows and signal LOCK.

9. OPERATOR INTERFACE: Interface accomplished via two sealed overlay

membrane switches.

10.
11. BATTERY LIFE: 90-120 hours. Automatic shutdown oc

curs 90

minutes

after idle (no switches pressed).

12. BATTERY STATUS: Continuous indication on the display.
13. ACCESS PORT: For coupler clamps.
14. TEMPERATURE RANGE (operational): -25 degrees Fahrenheit to 150

degrees Fahrenheit (-32 degrees Celsius to 65 degrees Celsius).

15.

3.2 cm D), typical.

16. WEIGHT: 5.3 lbs (2.4 kg).
17. CONSTRUCTION: ABS plastic weather resistant housing meets NEMA

3S and IP 54 standards.

18. RUGGEDNESS: Withstands three foot drops to ground (soil).