Heath Consultants Sure-Lock All Pro User Manual

Page 29

Advertising
background image

26

(Correct - Grounding attachment allows signal

(Correct. - The coupler clamp jaws are closed
around the conductor. The conductor is
energized)

(Incorrect - Terminated end (open circuit). The

(Incorrect - The coupler clamp jaws are
clamped to the conductor. The conductor is not
energized)

Figure 2-8

Figure 2-9

Conductive/ Inductive Mix

outputs are only available with the transmitter set to “ALL OUTPUT” mode.
With no conductive cables attached, the transmitter operates inductively for all
frequencies selected.

Attaching a conductive cable to a respective output will switch that output from
inductive to conductive mode. The other outputs will still be operating in the
inductive mode.

Using the Receiver
A correct understanding of the transmitter’s use is important to assure proper
signals at the receiver’s location. As a highly developed computerized instru-
ment, the Sure-Lock is capable of providing remarkable accuracy in a wide

Advertising