Cleaning and maintenance, Specifications, Service hints – Desa FVFM27NR/PR User Manual

Page 18: Technical service, Wiring diagram, Continued

Advertising
background image

108382-01E

18

For more information, visit www.desatech.com

For more information, visit www.desatech.com

1.

Shut off the unit, including the pilot. Allow the unit to cool for
at least thirty minutes.

2.

Inspect burner, pilot, and primary air inlet holes on injector
holder for dust and dirt (see Figure 32).

3.

Blow air through the ports/slots and holes in the burner.

4.

Check the injector holder located at the end of the burner tube
again. Remove any large particles of dust, dirt, lint, or pet hair
with a soft cloth or vacuum cleaner nozzle.

5.

Blow air into the primary air holes on the injector holder.

6.

In case any large clumps of dust have now been pushed into
the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes out
of the pilot assembly (see Figure 33). With the unit off, lightly blow
air through the air inlet hole. You may blow through a drinking straw
if compressed air is not available.

LOGS

• If you remove logs for cleaning, refer to Installing Logs, page

13, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized or larger).

CLEANING AND
MAINTENANCE

Continued

Figure 33 - Pilot Inlet Air Hole

Burner Tube

Pilot Assembly

Pilot Air
Inlet Hole

Ports/Slots

Figure 32 - Injector Holder On Outlet Burner Tube

Primary Air Inlet Holes
(Shape of Holes May
Vary by Model)

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder And Pilot Air Inlet Hole
Logs

WIRING DIAGRAM
SPECIFICATIONS
SERVICE HINTS
TECHNICAL SERVICE

Burner
Tube

Injector Holder
(May Be Brass or
Aluminum Depend-
ing on Model)

SPECIFICATIONS

Natural Gas

Propane/LP

Btu (Variable)

20,000/39,000

20,000/39,000

Type Gas

Natural Gas Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Manifold

3.5" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

14"

Minimum*

5"

11"

Shipping Weight

32 lbs.

32 lbs.

* For input adjustment

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local
natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA Heating Products’ Technical
Service Department at 1-866-672-6040. When calling please have
your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical services web
site at

www.desatech.com.

WIRING DIAGRAM

Note:

For proper operation of optional accessories, the wires from

the switch to the control must be connected exactly as shown.

AUT

O

OF

F

ON

Thermopile

Advertising