Grounding / double insulation instructions – Kent EWD-320 Wet/Dry Vacuums User Manual

Page 7

Advertising
background image

7

GROUNDING INSTRUCTIONS (USA, Canada)

Applicable to machines with a three-pin plug
T
his appliance must be grounded. If it should malfunction or
breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This appli-
ance is equipped with a cord having an equipment-grounding
conductor and grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.

DANGER!

Improper connection of an equipment-grounding conductor can
result in risk of electric shock. Check with qualifi ed electrician
or service person if you are in doubt as to whether the outlet
is properly grounded, Do not modify the plug provided with the
appliance. If it will not fi t the outlet, have proper outlet installed
by a qualifi ed technician.
This appliance is for use on a nominal 120 volt circuit and has
a grounding plug that looks like the plug illustrated in Figure A.
A temporary adaptor which looks like the adaptor illustrated in
Figure B may be used to connect this plug to a two-pole recep-
tacle, as shown, if a properly grounded outlet is not available.
The temporary adaptor should be used only until a properly
grounded outlet, Figure A, can be installed by a qualifi ed elec-
trician. The green colored rigid ear, lug, or the like extending
from the adaptor must be connected to a permanent ground
such as a properly grounded outlet box cover. Whenever the
adaptor is used, it must be held in place by a metal screw.

NOTE! This temporary adaptor is not permitted
in Canada

S E R V I C I N G O F D O U B L E - I N S U L AT E D

APPLIANCES

Applicable to machines with a two-pin plug
In a double-insulated appliance, two systems of insulation are
provided instead of grounding. No grounding means is pro-
vided on a double-insulated appliance, nor should a meand
for grounding be added to the appliance. Servicing a double-
insulated appliance requires extreme care and knowledge
of the system, and should be done only by qualifi ed service
personnel. Replacement parts for a double-insulated appliance
must be identical to the parts they replace. A double insulated
appliance is marked with the words
"DOUBLE INSULATION" or
"DOUBLE INSULATED."
The symbol (square within a square) may also be used on
the product.

FIGURE A

FIGURE B

SERVICE INFORMATION

To obtain consistent performance over the life of your vacuum,
read through these instructions and keep them handy for future
reference. If you require service, contact the dealer from whom
the vacuum was purchased, or the local authorized Service
Station. Always refer to your Service Station for complete ser-
vice information, For prompt and complete service information,
always refer to the model, type and serial number indicated on
the rating plate.

IMPORTANT

If the supply cord of this appliance is damaged, it must be
replaced by a repair shop appointed by the manufacturer as
special purpose tools are required.

GROUNDING BLADE IS LONGEST OF
THE THREE BLADES

GROUNDED OUTLET
BOX

GROUNDING

TAB

M E T A L
SCREW

ADAPTOR

GROUNDED
O U T L E T
BOX

GROUNDING / DOUBLE INSULATION INSTRUCTIONS

Advertising
This manual is related to the following products: