VENTING INSTALLATION

NOTICE: Failure to follow these

instructions will void the war-

ranty.

NOTICE: Do not seal termination

cap to vent pipe. Cap must be

removable for vent inspection

and maintenance.

INSTALLATION PRECAUTIONS

• Wear gloves and safety glasses for pro-

tection

• Use extreme caution when using ladders

or when on roof tops

• Be aware of electrical wiring locations in

walls and ceilings

The following actions will void the warranty
on your venting system:
• Installation of any damaged venting com-

ponent

• Unauthorized modification of the venting sys-

tem (Do not cut or alter vent components)

• Installation of any component part not

manufactured or approved by DESA Heat-
ing, LLC

• Installation other than as instructed by

these instructions

WARNING: This gas fireplace

and vent assembly must be

vented directly to the outside.

The venting system must NEVER

be attached to a chimney serv-

ing a separate solid fuel burning

appliance. Each direct-vent gas

appliance must use a separate

vent system. Do not use com-

mon vent systems.

WARNING: Vent pipe air

space clearances to combus-

tibles are 1" on all sides except

on the horizontal sections,

which require 2" clearances

from the top of the pipe. Where

the termination cap penetrates

a combustible wall, 1" air space

clearance is required.

NOTICE: Read these instruc-

tions completely before attempt-

ing installation.

These models are tested and approved for
use with DESA Heating, LLC (direct-vent) pipe
components and terminations.
The venting system must terminate on the out-
side of the structure and can not be attached
to a chimney or flue system serving a separate
solid fuel or gas burning appliance. A direct-vent
appliance must have its own venting system.
DO NOT common vent this appliance.
These models are approved to be vented
either horizontally through an outside wall or
vertically through a roof or chase enclosure
using the following guidelines:
• When venting system terminates horizon-

tally on an outside wall, you may install
a standoff if the termination cap is to be
installed directly on a combustible finish
such as vinyl, wood, stucco, etc.

• Never run the vent downward as this may

cause excessive temperatures which could
cause a fire.

• Vent pipe air space clearances to com-

bustibles are 1" on all sides except on the
horizontal sections, which requires 2" clear-
ance from the top of the pipe. Where the
termination cap penetrates a combustible
wall, 1" air space clearance is required.

• Snorkel terminations are required when

minimum clearance to grade cannot be
met (see Figure 16 on page 13).

• Have fireplace and selected vent compo-

nents on hand to help determine the exact
measurements when elbowing or offsetting.
Always use wall firestops when penetrating
walls and firestops when penetrating ceil-
ings or attic spaces.

• If using a venting configuration of only

horizontal venting with no vertical run, a
1/4" rise for every 12" of run toward the
termination is required.

• For installation of fireplace at elevations of

4000 feet or greater, pay special attention
to venting requirement recommendations.

WARNING: Read all instructions

completely and thoroughly before

attempting installation. Failure to

do so could result in serious injury,

property damage or loss of life.