Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 3/8" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

WARNING: For natural

gas, never connect heater to

private (non-utility) gas wells.

This gas is commonly known

as wellhead gas.

IMPORTANT:

For natural gas, check gas line

pressure before connecting heater to gas line. Gas

line pressure must be no greater than 10.5 inches of

water. If gas line pressure is higher, heater regula-

tor damage could occur.

CAUTION: For propane/LP

gas, never connect heater di-

rectly to the propane/LP supply.

This heater requires an external

regulator (not supplied). Install

the external regulator between the

heater and propane/LP supply.

For propane/LP gas, the installer must supply an

external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

the external regulator with the vent pointing down

as shown in Figure 14, page 12. Pointing the vent

down protects it from freezing rain or sleet.

MOUNTING HEATER TO FLOOR
(OPTIONAL)

Mounting Base Feet to Heater
1. Lay heater cabinet on its back on a table with

the heater bottom overhanging the table edge.

2. Align holes in base foot with mounting holes

on bottom of cabinet (see Figure 13).

3. Secure base foot to heater using sheet metal

screws.

4. Repeat for other side.
Mounting Base Feet to Floor (Where
required by local code)
1. Remove front cover (see Removing Front

Panel of Heater,

page 9).

2. Position heater with base feet in desired loca-

tion. Mark holes for drilling. Remove heater

with base.

3. For carpeted floors, make a small cut with a

sharp knife at marked locations prior to drill-

ing. If mounting base to a wood floor, drill

1/8" (3.2 mm) diameter hole, 3/4" (1.9 cm)

deep. (Do not use anchors in wood floors).

If mounting base to a concrete floor, drill with

1/4" (6.4 mm) diameter concrete drill bit, 1

3

/

8

"

(3.5 cm) into floor. Insert anchors completely

into holes.

4. Reposition heater with base feet over holes.

Secure base to floor with wood screws. See

Figure 13.

Figure 13 - Installing Base Feet

Wood
Screw

Sheet Metal Screw

Base Foot