Nursing Kelly

5

Laerdal

Blood Pressure Arm

1 . Place Blood Pressure Cuff on arm .
2 . Attach tubing on cuff to clear tube, located underneath Nursing Kelly’s

arm . (Photo 8)

See SimPad DFU for complete Blood Pressure operating
procedures.

Do not insert needles into blood pressure arm .

See SimPad DFU for complete Heart, Breath and Bowel
Sound Auscultation.

Genitalia

Both male and female genitalia have been provided for urinary
catheterization and enema training procedures .

Tube-like valves, with a screw cap on one end, connect urethra and anus to
corresponding reservoirs . This cap must be connected to genitalia openings .
Soft vinyl end of valve is attached to urinary reservoir with a black clamp
and anal reservoir with a white clamp . (White valve connects urinary
reservoir; flesh tone valve connects anal reservoir .)

Pelvic support pin must be removed and replaced immediately when
assembling and disassembling genitalia . (Figure 5) .

Pelvic support pin must be replaced.

Failure to replace pin will result in pelvic spread .

Should this occur, see Troubleshooting, page 6 .

If this occurs, the genitalia module will no longer fit properly

in the manikin .

To disassemble:
1 . Lift up on belly plate .
2 . Pull upper portion of genitalia back to remove pelvic support pin .
3 . Belly plate, genitalia with valves, and colon reservoir may now be

removed simultaneously .

To assemble: (Photos 9 & 10)
1 . Screw both valves onto genitalia . When attaching valves, be sure

alignment of genitalia, urinary reservoir (belly plate) and colon reservoir
are as illustrated in Figure 6 .

2 . Lift up on edge of belly plate .
3 . Pull down upper portion of genitalia .
4 . Insert into pelvic cavity .
5 . Replace the pelvic support pin .
6 . Press belly plate into position .

White valve connects urinary reservoir; flesh tone valve connects

anal reservoir .

Install white valve on the black connector of the urinary reservoir .

Insert white valve until it is flush with the urinary reservoir and secure the
black clamp as shown .

Colon Reservoir

Colon reservoir inserts into pelvic cavity with narrow end downward and
connector pointing outward . This connector attaches reservoir to anal valve
on genitalia . (Photo 11)

Reservoir should be removed from manikin, inverted, drained and
completely air-dried before storing .

English

Photo 8

Figure 5

Figure 6

Photo 9

Photo 10

Photo 11

Advertising