Maintenance

Ventilation

Lubricate airway with two or three sprays prior to starting your training session.

Lubricate airway management tools liberally prior to starting intubations. Consider whether

additional lubrication is needed later in the session.

Use only lubrication provided. Do not use silicon or other lubricant, as this may damage manikin.

Note
Head contains electrical components. Due to inability to sanitize airway, mouth-to-mouth/
mouth-to-mask ventilation should not be performed.

BP arm assembly and disassembly

For transportation using hard case you must disassemble BP arm.

To reassemble, reverse procedure.

Ensure grooves on bolt fit properly into hole on torso.

Reattach chest skin.

English

Press grooves to

release arm and

expose cable.

Detach cable.

Remove arm.