9.0

SPECIFICATIONS

Dimensions:

The unit has a T-shaped configuration.

Max. Unit width: 4.5”

Max. Unit height: 5.75”

Max. Unit depth: 3.5”

Note: See page 2 for dimensional images

Weight:

2 LBS.

AC Input:

90 – 240 VAC 50/60/400 Hz, 500 mA

AC Inlet:

Standard IEC-320 (60320) receptacle. 3 wire grounded.

Mates with USA and international IEC line cords. Internal

AC fuse protection.

AC Line Cord:

Provided: 6 ft. 3 Wire with IEC-320 plug one end and

standard NEMA 15-5, 125V plug on the other end. Change

line cord or use adapter plug for 230V input.

Ambient Operating temp: 0 to 40°C (32 – 104°F)

Storage Temp:

-40 to 80°C (-40 – 125°F)

Fan Cooled

DC OUTPUT

10 Amp max pulse for low batteries (below 18V), then approx. 3 ~ 5 Amps

electronic current and voltage limiting.

Charge regulation within AC line limits and low to full charge load ± 1%

RMS Ripple 0.25 %, except during pulsing. Pulsing 10A 1ms, 2 pulses / sec.

Internal AC and DC fuse protection.