Linear Scanner Pinouts

Pin Name

1, 3, 5

VS

2, 4, 6

GND

7, 8

EARTH GROUND

*9, 13

RS485 CABLE SHIELD

20, 40

RESERVED

35 TX

AUX

37 RX

AUX

DS2100A
DS2400A

DS4600A DS1100

DS2200

DS6XXX
DX6XXX

DS8100A

21

OUT1+ OUT1+ OUT1+ OUT1+

22 OUT

REF

OUT1-

IO

REF

OUT1-

23

OUT2+ OUT2+ OUT2+ OUT2+

24 OUT

REF

OUT2-

IO

REF

OUT2-

25 NC

RESERVED

NC

OUT

3A

26 NC

RESERVED

IN1-

OUT

3B

27

EXT TRIG+

EXT TRIG+

EXT TRIG+

EXT TRIG/PS

A

28

EXT TRIG-

EXT TRIG-

EXT TRIG-

EXT TRIG/PS

B

29

NC IN1+ NC

IN

2/ENC

A

30

NC

IN1-

IO REF

IN 2/ENC B

31

NC IN2+ NC IN

3A

32 NC

IN2-

NC

IN

4A

33 RESERVED

RESERVED RESERVED

IN

3A

34 RESERVED

RESERVED RESERVED

IN

4A

36

RTSA

GND

NC

IN 3B/IN 4B

38 CTSA

SGND

AUX

NC

GND

39

GND GND GND GND

DS2100A DS2400A DS4600A DS6XXX DX6XXX DS8100A

RS232 RS485FD

RS485HD 20mA

CL

(with INT-30 only)

*11, 15

TX232

TX485+

RTX485+

*12, 16

RTS232

TX485-

RTX485-

17 RX232

RX485+

18 CTS232

RX485-

*10, 14, 19

SGND MAIN SGND MAIN SGND MAIN

see INT-30
instructions

DS1100 DS2200

RS485HD

*11, 15

RTX485+

*12, 16

RTX485-

17

RESERVED

18

RESERVED

*10, 14, 19

SGND MAIN

* The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate

network connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In
this way the network bus can enter and exit the C-Box 100 from different spring clamps but be
physically connected together.

2D Reader/Camera Pinouts

Pin Name

1, 3, 5

VS

2, 4, 6

GND

7, 8

EARTH GROUND

20, 40

RESERVED

MATRIX-

2XXX

MATRIX-

1XXX

DV9500

*9, 13

RS485 CABLE SHIELD

RESERVED

35 TX

AUX

•RX2 232

37 RX

AUX

•TX2 232

21 OUT1+

NC

RESERVED

22 OUT1-

NC

RESERVED

23 OUT2+

NC

GND3

24 OUT2-

NC

OUTPUT+

25 OUT3+

OUT3+

TX3

485-

26 OUT3-

OUT3- TX3

485+

27

EXT TRIG A

EXT TRIG A

RX3 485-

28

EXT TRIG B

EXT TRIG B

RX3 485+

29 IN

2A

NC

PS-

30 IN

2B

NC

PS+

31 NC

NC

OE+

32 NC

NC

OE-

33 NC

NC

OE+

34 NC

NC

OE-

36 NC

NC OUTPUT-

38 GND

GND

•GND2

39 GND

GND

GND

• These signals are not available by default but require DV9500 internal jumper settings.

MATRIX-2XXX

RS232 RS485FD

RS485HD 20mA

CL

(with INT-30 only)

*11, 15

TX232

TX485+

RTX485+

*12, 16

RTS232

TX485-

RTX485-

17 RX232

RX485+

18 CTS232

RX485-

*10, 14, 19

SGND MAIN SGND MAIN SGND MAIN

see INT-30
instructions

MATRIX-1XXX

RS485HD

*11, 15

RTX485+

*12, 16

RTX485-

17

NC

18

NC

*10, 14, 19

SGND MAIN

DV9500

*11,

15

INPUT-

*12,

16

•GND1

17

INPUT+

18

•RX1 232

*10, 14, 19

•TX1 232

• These signals are not available by default but require DV9500 internal jumper settings.



SCANNER SELECTION

A

DS1100
DS2200

Other Devices

B

Figure 8 - Scanner Selection


Switch S3 must be set to A only when a DS1100 or a DS2200 scanner
(10-30 V version) is connected. For all the other devices switch S3 must
be set to B.


RS485 BUS TERMINATION

ON

S2

OFF

Figure 9 - Termination Resistance Switch


Switch S2 enables or disables the insertion of the bus termination
resistor for RS485 Half Duplex Multidrop applications.

CAUTION

In Multiplexer applications the termination resistor
must be enabled ONLY on the last device of the
chain, the farthest away from the Multiplexer
(assuming the Multiplexer is the first device of the
chain). On all the other devices this resistor MUST
NOT be enabled (S2 = OFF).


NOTE

For all RS485 connections, in case of electrically noisy
environments: C-BOX 100 should be connected to a
good earth ground (pin 7 or 8), RS485 CABLE SHIELD
should be connected to pin 7 or 8, the scanner chassis
should be connected to EARTH GROUND through the
jumper, see Figure 7.








821000554 (Rev. E)

OM4000 JUMPER SETTINGS

J1

J2

Figure 10 - OM4000 Jumpers


These jumpers allow connection to the EXT TRIG signals on separate
spring clamp terminals for applications which use the OM4000
Oscillating Mirror in Trigger Mode.

When jumper J1 is inserted, pin 40 is connected to pin 27 (EXT TRIG+);
jumper J2 inserted connects pin 20 to pin 28 (EXT TRIG-).

When the jumpers are removed, pin 20 and pin 40 are disconnected.


9-PIN SCANNER AUXILIARY SERIAL INTERFACE

The scanner auxiliary serial interface available on the internal 9-pin
connector can be used either for configuration or for data monitoring.

The details of the connector pins are indicated in the following table:

Figure 11 - 9-pin Male Connector

9-pin Connector Pinout

Pin Name Function

1

N.C.

2 RXA

Auxiliary

RS232

3 TXA

Auxiliary

RS232

4

N.C.

5 GND

Ground

6

N.C.

7 RESERVED

Device

Dependent

Signal

8 RESERVED

Device

Dependent

Signal

9

N.C.

NOTE

Pins 7 and 8 have different signals attributed to them
depending on the device connected to C-BOX 100. It
is recommended to use only pins 2, 3, and 5 for
communications.


CAUTION

Do not use the 9-pin connector when C-BOX 100 is
connected to DV9500.



TECHNICAL FEATURES

ELECTRICAL FEATURES

Supply Voltage

10 to 30 Vdc*

Power Consumption

0.5 W + scanner power

consumption

(see related manual)

Max Current Consumption

(short circuit protection on 25-pin
connector)

2 to 2.5 A

USER INTERFACE

LED Indicators

Power on LED (green)

Power polarity error LED (red)


* for further details about minimum/maximum supply voltage refer to

the manual of the connected scanner, since the minimum supply
voltage required may be >10.

PHYSICAL FEATURES

Mechanical Dimensions

161 x 114.5 x 40 mm

(6.34 x 4.51 x 1.57 in.)

Weight

about 320 g. (11.29 oz.)

ENVIRONMENTAL FEATURES
Operating Temperature

-10° to 50

°C (+14° to 122 °F)

Storage Temperature

-20° to 70

°C (-4° to 158 °F)

Humidity max.

90% non condensing

Vibration Resistance

14 mm @ 2 to 10 Hz

EN 60068-2-6
2 hours on each axis

1.5 mm @ 13 to 55 Hz

2 g @ 70 to 200 Hz

Shock Resistance

30 g; 11 ms;

EN 60068-2-27

3 shocks on each axis

Protection Class

IP64

(when correctly connected to the scanner)

The features given are typical at a 25

°C ambient temperature (if not otherwise

indicated).


WEEE COMPLIANCE


Information for the user in accordance with the European Commission
Directive 2002/96/EC


At the end of its useful life, the product marked with the crossed out wheeled
wastebin must be disposed of separately from urban waste.

Disposing of the product according to this Directive:

• avoids potentially negative consequences to the environment and human health which

otherwise could be caused by incorrect disposal

• enables the recovery of materials to obtain a significant savings of energy and resources.


For more detailed information about disposal, contact the supplier that provided you with the
product in question or consult the dedicated section at the website
www.automation.datalogic.com.


CE COMPLIANCE

Warning: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.

DECLARATION OF CONFORMITY

07

Datalogic Automation S.r.l.

Via S. Vitalino 13

40012 - Lippo di Calderara

Bologna - Italy

dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
C-BOX 100, passive connection box

e tutti i suoi modelli

and all its models

et tous ses modèles

und seine modelle

y todos sus modelos

sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below:
sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous:
der nachstehend angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
89/336/EEC EMC Directive e 92/31/EEC, 93/68/EEC

emendamenti successivi

and further

amendments

et

ses successifs amendements

und späteren

Abänderungen

y succesivas

enmiendas

Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed
alla sicurezza dei prodotti.
On the approximation of the laws of Member States relating to electromagnetic compatibility and
product safety.
Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la
sécurité des produits.
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische
Verträglichkeit und Produktsicherheit entsprechen.
Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad
electromagnética y las Medidas de seguridad relativas al producto.

Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:

EN 55022, August 1994:
Amendment A1 (Class A ITE), October 2000:

L

IMITS AND METHODS OF MEASUREMENTS OF RADIO

DISTURBANCE CHARACTERISTICS OF INFORMATION
TECHNOLOGY EQUIPMENT

EN 61000-6-2, October 2001:

E

LECTROMAGNETIC COMPATIBILITY

(EMC)

P

ART

6-2: G

ENERIC

S

TANDARDS

– I

MMUNITY FOR

INDUSTRIAL ENVIRONMENTS

Lippo di Calderara, April 2nd, 2007

Lorenzo Girotti

Product & Process Quality Manager

Advertising