Page – Lingenfelter L460220000 Lingenfelter TBRC-001 Temperature Based Relay Controller v1.0 User Manual
Page 8

Page
Temperature
Temperature sensor type (settings group on TBRC-001)
GM ECT/IAT/TFT
(use settings 0-3)
AEM / Autometer
1/8 NPT
(use settings 4-7)
GM / AEM / Bosch
/ Sensata EGT
Platinum RTD
(use settings 8-B)
Sensor Group
(settings C-F)
Currently Unused
°C
°F
Resistance values measured in Ohms
-40
-40
100700
402000
170
-
-30
-22
52700
210000
178
-
-20
-4
28680
114000
185
-
-10
14
16180
64300
193
-
0
32
9420
37500
201
-
10
50
5670
22500
208
-
20
68
3520
14000
216
-
30
86
2238
8900
224
-
40
104
1459
5800
231
-
50
122
973
3900
239
-
60
140
667
2700
246
-
70
158
467
1900
254
-
80
176
332
1300
261
-
90
194
241
965
268
-
100
212
177
710
276
-
110
230
132
531
284
-
120
248
100
403
291
-
130
266
77
309
299
-
140
284
60
241
306
-
150
302
47
189
313
-
200
392
-
-
349
-
300
572
-
-
420
-
400
752
-
-
488
-
500
932
-
-
554
-
600
1112
-
-
618
-
700
1292
-
-
679
-
800
1472
-
-
738
-
Table 3: Temperature Sensor Resistance vs. Temperature
7.
• All resistance values shown above are approximate and will be different based on which
specific temperature sensor you use.