Lingenfelter L480330000 SPDT microswitch kit v1.2 User Manual
Page 2

Installation:
1. Slide a supplied cable seal on each of the microswitch wires.
2. Crimp a supplied female terminal to each of the microswitch wires that you installed a cable seal
onto in the last step.
3. Insert the terminated wires into the female connector.
4. Repeat steps 1-3 for the male connector, with the exception of installing a cavity plug in place of
any wire that will not be used to enable a device.
5. Connect the switch inline with the device to be enabled.
6. Mount the microswitch in a location that will allow the microswitch to enable the device at the
desired pedal or throttle body position.
Lingenfelter Performance Engineering
1557 Winchester Road
Decatur, IN 46733
(260) 724-2552
(260) 724-8761 fax
www.lingenfelter.com
Mounting dimensions
Normally Closed (NC)
Normally Open (NO)
Common
NO
NC
COM
Inputs/outputs
can be voltage
or ground
Microswitch pin-outs:
For additional product installation information and technical support, contact LPE or your LPE
products distributor. You can also find technical support and usage discussions regarding
this product and many other LPE products in our Internet forums:
http://www.lingenfelter.com/LPEforumfiles
L480330000 SPDT microswitch kit v1.2.indd