Owner’s manual, Troubleshooting, Continued – Desa CGR2N User Manual

Page 15

Advertising
background image

15

107292

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating heater where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

Heater produces unwanted odors

Heater shuts off in use (ODS operates)

Gas odor even when control knob is in OFF
position

Gas odor during combustion

Moisture/condensation noticed on windows

POSSIBLE CAUSE

1. Heater burning vapors from paint, hair

spray, glues, etc., (see

IMPORTANT

statement above)

2. Gas leak.

See Warning statement at

top of page

1. Not enough fresh air is available

2. Low line pressure
3. ODS/pilot is partially clogged

1. Gas leak.

See Warning statement at

top of page

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak.

See Warning statement at

top of page

1. Not enough combustion/ventilation air

REMEDY

1. Ventilate room. Stop using odor-causing

products while heater is running

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 10)

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

2. Contact local natural gas company
3. Clean ODS/pilot (see Cleaning and

Maintenance, page 12)

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 10)

2. Replace control valve

1. Take apart gas tubing and remove for-

eign matter

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 10)

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

www.desatech.com