Control box settings, Dip switches – Mighty Mule FM500 Blue Board User Manual

Page 28

Advertising
background image

Control Box Settings

15

DIP#1

ON**___Soft start enabled (factory preset).

OFF __Soft start disabled.

DIP#2

ON**___Buzzer warning enabled (factory preset).

OFF __ Buzzer warning disabled.

DIP#3

ON*___Push-to-open.

OFF*__Pull-to-open (factory preset).

DIP#4

ON*___Slave opens simultaneously with master.

OFF*__Slave opens after master. (factory preset).

NOTE: Not applicable for single gate operator.

*factory

presets shown

*factory

presets shown

1

2

3

4

DIP#6

DIP#7

Delay Time for Auto-Close

ON

ON

15 seconds

ON

OFF

30 seconds

OFF

ON

60 seconds

OFF*

OFF*

120 seconds

1

2

3

4

O

N

DIP Switch #1 - Soft Start/Stop
The soft start/stop feature slowly starts the gate as it
begins to open or close and slows the gate as it comes
to the opened or closed position. This saves wear and
tear on the gate and gate opener system.

DIP Switch #2 - Warning Buzzer
The warning buzzer alerts you when the gate opener
is beginning to either open or close the gate. It sounds
for the first 2 seconds in each direction. It also sounds
a warning when the gate obstructs two times in one
cycle. Switching this to OFF only disables the open
and close warning not the obstruction warning.

DIP Switch #3 - Push/Pull-to-Open
If your gate opens into the property the DIP Switch is
set to the OFF position (factory setting). If your gate
opens out from the property the DIP Switch must be
set to the ON position. NOTE: if you have a Push-to-
Open gate application you will need a Push-to-Open
bracket (see Push-to-Open Instructions on page 16).

DIP Switch #4 - Delay/Simultaneous operation
If set to ON the slave opens simultaneously with the
master. If set to OFF the slave opens after the master.
NOTE: Not applicable for single gate operator.

DIP Switches

25

IMPORTANT: Before making any changes to dip switches turn control box off!

Advertising