Mighty Mule MM362-D User Manual

Page 30

Advertising
background image

20

Mighty Mule 362-D Installation Instructions

rev 07/19/11

Step 3: Attach Opener Arm (page 10)
Step 4: Install Closed Position Stop Plates (page 11)
Step 5: Mount the Control Box (page 12)
Step 6: Connect Opener Power Cables (page 13)
Step 7: Connect the Transformer (page 13) OR Solar Charger (page 21)
Step 8: Connect Battery Harness (page 15)
Step 9: Connect Battery (page 16)
Step 10: Remove Push-To-Open Jumper

A. Make sure the control box power switch is OFF.

B. Use small pliers to move the JUMPER for PUSH-TO-OPEN

applications.

C. Turn power switch ON. The control board is now configured to

push the gate open. (Keep the jumper, as it is necessary if there

is ever a need to convert the opener for Pull-To-Open).

Step 11: Set the Open Position Limit (Push-to-Open)
Note: Must have a transmitter that operates the gate. If not see Personalize Your Transmitter Setting on page 18.
The CLOSED limit is when the opener is fully retracted and the gate is in the closed position. The closed limit setting can

only be adjusted by moving the gate bracket. To acheive the optimum open position, you must adjust the OPEN Limit

setting:

A. If not already ON slide the ON/OFF switch on the Control Box to the ON position and make sure the arms are in

the CLOSED POSITION (fully retracted).

B. Press and HOLD the FIRST Opener

OPEN button on the control board and

be prepared to RELEASE the button

when the gates reached the desired

open position/limit. Use the JOG

OPEN and CLOSE buttons to "fine

tune" the gate position if neccessary.

C. Press and HOLD the SECOND Opener

OPEN button on the control board and

be prepared to RELEASE the button

when the gates reached the desired

open position/limit. Use the JOG

OPEN and CLOSE buttons to "fine

tune" the gate position if neccessary.

D. NOTE: The opener arms must be extended more than 7 inches to set limits. With the gates in in the desired

open positions PRESS and HOLD the SET LIMIT button until the alarm and RED Light come on. Then release the

button.

E. NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet. Press the

transmitter button once and allow the gates to fully close. The alarm will beep once when both gates reach the

CLOSED LIMIT. This indicates the LIMITS for both arms are learned and stored in memory

F. Press the transmitter button and allow the gates to fully open to verify that they stop at the desired positions.

Repeat Steps B – E if correction is needed.

Step 12: Adjust Stall Force Setting (page 17)
Step 13: Set Auto Close Time (page 17)
Step 13: Personalize Transmitter Settings (page 18)

MIN

MAX OFF

REMOVE JUMPER FOR

PUSH TO OPEN OPTION

120

SEC.

STALL FORCE

OPEN < JOG > CLOSE

PWR.

SET

LIMIT

1st OPR.

2nd OPR.

STATUS

AUTO CLOSE

FIRST Opener

JOG Buttons

SET LIMIT Button

SET LIMIT Light

SECOND Opener

JOG Buttons

MIN

MAX OFF

REMOVE JUMPER FOR

PUSH TO OPEN OPTION

120

SEC.

STALL FORCE

OPEN < JOG > CLOSE

PWR.

SET

LIMIT

1st OPR.

2nd OPR.

STATUS

AUTO CLOSE

Push-To-Open Jumper

Advertising