Installation overview wiring the wand, Important – Mighty Mule FM138 User Manual

Page 2

Advertising
background image

2 GTO Exit Wand Instructions 12.28.11

• The SENSOR is designed to detect iron-

based metal

in motion.

• The SENSOR’s ability to detect iron-based

metal objects is based on the mass, velocity
and proximity of the object to the sensor.

EXAMPLE - A child’s bicycle moving at 2
mph @ 1’ from the sensor has a similar
effect as a car moving at 2 mph @ 6’ from
the sensor.

• The SENSOR must be stationary to function

properly.

Gate Opener

Control Box

Driveway

RANGE:

12 ft. radius

(max)

SENSOR:

2 ft. from Driveway (max)

and12 in. deep

Open Gate

Outside Sensor

Range

( allow 5 ft. for wiring

to Control Box)

Gate Opener

Control Box

12”

Minimum of 25 feet

SENSOR: 2 feet from

driveway edge and

1 foot in ground

Open Gate

Outside Sensor

Range

PVC conduit in ground

and up to control box

recommended

24”

1.

Obtain the instruction manual for the
gate opener.

2.

Locate the control terminals (2) that
will

ONLY OPEN the gate.

3.

Verify that the above inputs when
shorted (a small wire connecting
the 2 terminals) will do all of the
following:

• OPEN the gate if the gate is idle.

• STOP and then OPEN the gate if gate is closing.

• DO NOTHING if the gate is opening.

Yellow

Black

Blue

RELAY OUTPUT

POWER INPUT =

Red

Braided

Ground

WAND

WIRING

11-30 Vdc

or

8-26 Vac

TO

OPEN ONLY

INPUT OF GATE

OPENER CONTROL

Normally open relay contacts,

closes for 2 seconds when

moving vehicle is detected.

+

IMPORTANT

DO NOT CONNECT THE POWER
INPUT WIRES TO THE POWER
SOURCE (i.e. 12 V battery) UNTIL
INSTRUCTED TO DO SO.

INSTALLATION OVERVIEW

WIRING THE WAND

Advertising