Important, Turn gate opener off, Wiring diagram examples – Mighty Mule FM138 User Manual

Page 3: Turn opener on and test

Advertising
background image

GTO Exit Wand Instructions 12.28.11 3

4.

Connect the

BLACK to the terminal labeled COMMON, and

the

BLUE wire to terminal in STEP 3 to open gate.

5.

Connect the

POWER INPUT wires to power source.

Connect the YELLOW and

BRAIDED GROUND wires

to the (–)

NEGATIVE side of

power source. (i.e. battery)

Connect the RED wire to the

(+) POSITIVE side of power

source. (i.e. battery)

6.

Turn opener

ON and TEST.

TURN GATE OPENER OFF

ON

ALARM

ACCESSORY

RCVR

SEQ1

SEQ2

LEARN

BLU

ORG

WHT

GRN

R B G

Connect the

BLUE wire from

the

SENSOR CABLE to the

BLU terminal on the opener

control board.

Connect the

Black

wire from the

SENSOR

CABLE to one of the

COMMON terminals on the

opener control board.

BLUE

BLACK

RECR

GRN

BLK

RED

EXIT

SAFETY

EDGE

CY

CLE

COMMON

LINK

Connect the

BLUE wire from

the

SENSOR CABLE to the

EXIT terminal on the opener

control board.

Connect the

BLACK wire from the

SENSOR CABLE to one of the

COMMON terminals on the

opener control board.

BLUE

BLACK

RECEIVER

ALM

GTO RCVR.

CO

M

GRN

BLK

RED

CY

CLE

SAFET

Y

EXIT

SHADO

W

OPEN EDGE

CO

M

CONTROL INPUTS

CL

OSE

EDGE

Connect the

BLUE wire from the

SENSOR CABLE to the EXIT

terminal on the opener control

board.

Connect the

BLACK wire from

the

SENSOR CABLE to one

of the

COMMON terminals on

the opener control board.

BLUE

BLACK

COM

COM

COM

G

TO Inc.

SX4000 L

CY

CLE

SAFETY

OPEN EDGE

RUN 2

OPEN

CL

OSE

STOP

COM

COM

COM

SHADOW

LOOP

Connect the

BLUE wire

from the

SENSOR CABLE

to the

OPEN terminal on

the opener control board.

Connect the

BLACK wire from

the

SENSOR CABLE to one

of the

COMMON terminals on

the opener control board.

BLUE

BLACK

WIRING DIAGRAM EXAMPLES

NOTE: Power Input Connections Not Shown.

(See gate instruction manual for complete instructions)

BRAIDED GROUND

from SENSOR Cable

YELLOW wire from

SENSOR CABLE

RED wire from SENSOR Cable

Battery Cable

BLACK (-)

BLACK BATTERY CONNECTION WIRE

with Spade Connector included with SENSOR

RED BATTERY CONNECTION WIRE

with Spade Connector included with SENSOR

Double Spade Connectors

included with SENSOR

Battery Cable

RED (+)

IMPORTANT

WHEN THE WAND IS FIRST POWERED UP IT
MUST BE UNDISTURBED FOR 60 SECONDS TO
PERFORM THE SELF TEST AND CALIBRATIONS.
BEFORE POWERING THE WAND MAKE SURE
THERE ARE NO MOVING METAL OBJECTS OR
MOVING VEHICLES WITHIN THE RANGE OF
THE WAND

VAR5

K1

PF1

K2

BA

T

T

+

K3

K4

VAR4

VAR3

VAR2

VAR1

PW

R.

SF

TY

.

EXIT

CY

CLE

EDGE

SENSOR

COMMON

LOCK+

LOCK–

WHT

GRN

RED

BLK

WHT

GRN

SECOND OPR.

FIRST OPR.

RED

BLK

14 V

AC

OR

SOLAR

Connect the

BLUE wire from

the

SENSOR CABLE to the

EXIT terminal on the opener

control board.

Connect the

Black

wire from the

SENSOR

CABLE to one of the

COMMON terminals on the

opener control board.

BLUE

BLACK

Connect the

BLUE wire from

the

SENSOR CABLE to the

EXIT terminal on the opener

control board.

Connect the

Black

wire from the

SENSOR

CABLE to one of the

COMMON terminals on the

opener control board.

BLACK

POWER

CHGR

CHGR

EDGE

CY

CLE

EXIT

SAFETY

COM

COM

LOCK+

LOCK -

BLUE

Advertising