Warranty, Nemoid™ foot pump, Integrated pump – NEMO Equipment INTEGRATED PUMP User Manual

Page 2: Repair, Warnings

Advertising
background image

WARRANTY

NEMO guarantees every product we sell. We put a great effort into

choosing the best materials and providing you with the highest level of

workmanship. If one of our products does not meet your expectations

during its useful life, we promise to repair it, replace it, exchange it, or

give you a refund at our discretion. NEMO does not warranty products

against normal wear and tear, unauthorized modifications or alterations,

improper use, improper maintenance, misuse or neglect or if the

product is used for a purpose for which it is not intended. Except as

expressly set forth in these terms and conditions, NEMO is not liable for

any direct, indirect or consequential damages arising out of or resulting

from the use of a NEMO product. The warranties set forth in these terms

and conditions are in lieu of all other warranties, express or implied,

including without limitation, implied warranties of merchantability or

fitness for a particular purpose.

When using a supplamentry pump in combination with the

Integrated Pump (i.e. a bike pump) via the optional input/moisture

release valve be sure not to overinflate the airbeams.

The one-way check valve on the Intgrated Pump can get blocked

with saliva. If this happens, give it a hard shake or use a pen or stick

to release it.

WARNINGS

3

4

5

NEMOID™ FOOT PUMP

To inflate a NEMO airbeam, connect the quick-disconnect fitting on the

end of your Nemoid™ foot pump to the inflate/deflate valve at the base

of the airbeam. When properly connected, there will be an audible click.

Make sure the red Dump Check Valve™ is open. This will allow to air to

refill the pump body after every time you step on it.

When the airbeam is at the correct pressure you will find it very difficult

to compress the pump again. AirSupported Technology™ is a low

pressure system that runs at about 7 psi for a very rigid and strong tent.

The airbeams are strong enough to contain a much higher pressure

than will ever be reached with a NEMO pump.

1

2

Begin applying force to the foot pump by stepping on the pump body;

NEMO shield up. If you are pumping from inside the tent, it may be

easier to use your knee or hand to apply force.

3

4

When the airbeam is at the correct pressure you will find it very difficult

to compress the pump again. Disconnect the quick-disconnect fitting

from the airbeam and return the pump to your stuff sack for storage.

6

5

To inflate a NEMO airbeam with an Integrated Pump, first connect the

quick-disconnect fitting on the end of your pump to the inflate/deflate

valve at the base of the airbeam. When properly connected, there will

be an audible click.

Make sure the optional input/moisture release valve is closed. This

will allow you to fill the pump body with air.

Sqeeze this inflated pouch into the airbeam with your hand. A one-way

valve in the pump will prevent the air from coming back out.

Repeat the cycle of blowing and squeezing until the airbeam is rigid.

After a bit of practice, inflation can become quite quick. Remember to

frequently inhale too!

1

2

While holding the the pump body with one hand and the mouthpiece

to your mouth with the other, blow to inflate the pump body.

3

4

5

INTEGRATED PUMP

2

If you have any problems with a NEMO product, please contact Rainy

Pass Repair, Inc., the industry leader in outdoor product care for repair or

replacement. If you have any questions regarding warranty and repair,

or if you need to send a product in for service, please call Rainy Pass. It is

not necessary to clean the item before sending, but it will be

appreciated if you remove any excessive soiling. Rainy Pass will be

happy to give you advice about safely cleaning your product. Please

provide the following when you send a NEMO product to Rainy Pass:

A note with your name, phone number, address, e-mail and

problem description. A repair form can be downloaded at:

www.nemoequipment.com/pdf/NEMO_repairform.pdf

Please remove all of your personal items and mark all damaged

areas on the product with masking tape.

Pack the product in a sturdy cardboard box with plenty of room. If

possible, use the original box to reduce waste.

If you live in the Seattle area, you can call Rainy Pass locally at (206)

523-8135 and visit their shop during the following hours: M,T,W,F

9am-6pm and Th 9am-7pm.

Ship to:

Rainy Pass Repair, Inc.

5307 Roosevelt Way, NE

Seattle, WA 98105

To contact Rainy Pass:

Phone: 1 (888) 747-7867

Email: [email protected]

www.rainypass.com

REPAIR

5

2

1

3

1

When the beam is fully inflated, disconnect the quick-disconnect fitting

from the airbeam and return the pump to your stuff sack for storage.

For compact packing close the red Dump Check Valve™ and compress.

However, if you are going to be storing your Nemoid™ foot pump for a

prolonged period of time, it should be left uncompressed.

Be careful not to over-inflate if using a supplementary inflation device
through the input valve.

*

Advertising
This manual is related to the following products: