Warranty, Technical specifications – OPTI-UPS DS3000B-RM User Manual

Page 18

Advertising
background image

27

9. Warranty

Warranty on this product is valid against defects in material and workmanship
for a period of 24 months from its original date of purchase.

10. Technical Specifications

10.1 Power Range 1000-3000 VA (100/110/120V)

GENERAL

Rated power

1000 VA, 1500VA, 2000 VA, 3000 VA at p.f 0.7

Technology

On-line, double conversion topology with automatic bypass

INPUT

Phase:

Single phase with ground

Bypass Voltage

96--138 VAC (user selectable)

Input Voltage range:

60/70/80VAC-144 VAC

Frequency:

50/60 Hz. Auto selection

Frequency window from mains

45-65 Hz

Synchronization window

± 3Hz.

Input current

1000 VA 8.2A, 1500 VA 12.3A, 2000 VA 16.5A, 3000 VA 24.7A

Input Power factor:

0.97

OUTPUT

Output Voltage:

100/110/115/120/127 VAC, selectable from LCD panel

Voltage regulation:

± 2%

Voltage distortion:

< 5% THD at full non-linear load, < 3% THD at full linear load

Frequency regulation

± 0.25 Hz (battery or free running mode)

* 60V at 40% load, 70V at 70%, 80V at 100%.

ENVIRONMENTAL

Ambient temperature:

+0 °C to +40 °C

Recommended temperature:

+15 °C to +25 °C

Storage temperature:

-15 °C to +50 °C

Cooling: Forced

air-cooling

Humidity: 0-95%,

non-condensing

Audible noise:

< 40 db normal and battery mode

10.2 Power Range 1000-3000 VA (220/230/240V)

GENERAL

Rated power

1000 VA, 1500 VA, 2000 VA, 3000 VA at p.f. 0.7

Technology

On-line, double conversion topology with automatic bypass

INPUT

Phase

Single phase with ground

Bypass Voltage:

184-265 VAC (user selectable)

28

Input Voltage range:

120/140/160 VAC-276 VAC

Frequency:

50/60 Hz. Auto selection

Frequency window from mains

45-65 Hz

Synchronization window

± 3Hz.

Input current

1000 VA 4A, 1500 VA 6A, 2000 VA 7.7A, 3000 VA 12A

Input Power factor:

0.97

OUTPUT

Output Voltage:

208/220/230/240 VAC, selectable from LCD panel

Voltage regulation:

± 2%

Voltage distortion:

< 5% THD at full non-linear load, < 3% THD at full linear load

Frequency regulation

± 0.25 Hz (battery or free running mode)

* 120V at 40% load, 140V at 70%, 160V at 100%.

Dynamic response:

± 9 % max from 100% to 20 % or from 20% to 100 % linear load

Overload capacity:

100-125% 1 min, 125-150% 10 sec

Efficiency:

greater than 86%

ENVIRONMENTAL

Ambient temperature:

+0 °C to +40 °C

Recommended temperature:

+15 °C to +25 °C

Storage temperature:

-15 °C to +50 °C

Cooling: Forced

air-cooling

Humidity: 0-95%,

non-condensing

Audible noise:

< 40 db normal and battery mode

10.3 Power Range 1000-3000 VA (100/110/120V 19” Rack-mount

model)

GENERAL

Rated power

1000 VA, 1500 VA, 2000 VA, 3000 VA at p.f. 0.7

Technology

On-line, double conversion topology with automatic bypass

INPUT

Phase:

Single phase with ground

Bypass Voltage

96--138 VAC (user selectable)

Input Voltage range:

60/70/80VAC-144 VAC

Frequency:

50/60 Hz. Auto selection

Frequency window from mains

45-65 Hz

Synchronization window

± 3Hz.

Input current

1000 VA 8.2A, 1500 VA 12.3A, 2000 VA 16.5A, 3000 VA 24.7A

Input Power factor:

0.97

OUTPUT

Output Voltage:

100/110/115/120/127 VAC, selectable from LCD panel

Voltage regulation:

± 2%

Voltage distortion:

< 5% THD at full non-linear load, < 3% THD at full linear load