Sunlite® technical guide – Palram SUNLIT User Manual

Page 9

Advertising
background image

SUNLITE® Technical Guide

7

7

Maximum Recommended Spans between Arched Supports
According to radius of curve and load for two sides clamped glazing.

Structure

Thickness

Sheet curvature

radius

Recommended (center-to-center) Distance between Supporting arches

according to wind/Snow loads below

50 Kg/m²

10 psf

80 Kg/m²

16 psf

100 Kg/m²

20 psf

120 Kg/m²

24.6 psf

mm

mm

Inch

mm

Inch

mm

Inch

mm

Inch

mm

Inch

Twin Wall

6

1050

41

2000

79

1730

68

1420

56

1020

40

1500

59

1470

58

1090

43

890

35

660

26

1800

71

1140

45

860

34

690

27

580

23

2200

88

810

32

690

27

-

-

-

-

2800

110

500

20

350

14

-

-

-

-

4000

158

500

20

350

14

-

-

-

-

6000

236

500

20

350

14

-

-

-

-

8

1400

55

1650

65

1450

57

1320

52

1170

46

1800

71

1420

56

1270

50

1070

42

890

35

2200

88

1090

43

890

35

710

28

600

24

2800

110

840

33

620

19

450

18

-

-

4000

158

600

24

500

19

-

-

-

-

6000

236

570

23

480

19

-

-

-

-

10

1750

69

1630

68

1420

56

1170

46

1020

40

2200

88

1320

52

960

38

810

32

660

26

2800

110

890

35

650

26

600

24

550

22

4000

158

750

29

550

22

500

20

450

18

6000

236

700

27

520

21

500

20

420

18

Triple Wall

8

1760

70

1320

52

1170

46

980

39

750

30

2200

87

1025

41

780

31

580

23

520

21

2800

110

750

30

570

23

400

16

-

-

4000

158

500

20

450

18

-

-

-

-

6000

236

480

19

400

16

-

-

-

-

10

2200

88

1220

48

880

35

720

29

580

23

2800

110

780

31

580

23

500

20

450

18

4000

158

620

25

500

20

450

18

400

16

6000

236

550

22

450

18

400

16

-

-

16

2800

118

1850

73

1650

65

1450

57

1200

48

4000

158

1450

57

1220

48

940

37

850

34

6000

236

1050

42

1000

40

850

34

800

32

X-Lite

16

3000

120

1750

69

1600

63

1500

59

1400

55

5000

200

1350

53

1200

47

1100

43

1000

39

25

5000

197

1650

64

1450

57

1400

55

1350

53

6000

236

1550

61

1350

53

1300

51

1250

49

32

6400

252

1650

64

1550

61

1350

53

1300

51

8000

315

1550

61

1450

57

1250

49

1200

47

35

7000

276

1650

65

1550

61

1350

53

1300

51

8200

322

1550

61

1450

57

1250

49

1200

47

Notes:
1. A hyphen sign in the table (-) means that the sheet cannot be used at the relevant range.
2. Generally a span of less than 600 mm (24 in.) is impractical for this installation configuration.
3. The lowest radius that appears in the upper row of every sheet group in the table is the minimum permitted cold bending radius for that specific sheet type.