Checking gas connections, Continued – Desa 101811-01C.pdf User Manual

Page 16

Advertising
background image

16

101811

3. Pressurize supply piping system by either using compressed air or

opening propane supply tank valve.

4. Check all joints of gas supply piping system. Apply mixture of liquid soap and

water to gas joints. Bubbles forming show a leak.

5. Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1. Close manual shutoff valve (see Figure 15).
2. Pressurize supply piping system by either using compressed air or opening

propane supply tank valve.

3. Check all joints from propane supply tank to manual shutoff valve (see Figure

16). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.

4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1. Open manual shutoff valve (see Figure 15).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure

16). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 17 through 19). Check all other

internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Appliance, page 19).
8. Replace front panel.

Figure 16 - Checking Gas Joints

Manual
Shutoff
Valve

Propane
Supply Tank

ON

POSITION

OFF

POSITION

Open

Closed

Manual
Shutoff
Valve

Figure 15 - Manual Shutoff Valve

CHECKING

GAS

CONNECTIONS

Continued

Thermostat Gas Valve

Advertising