Installation, Continued – Desa VI33NR VI33PR User Manual

Page 11

Advertising
background image

111285-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

11

11

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

Supplied Flexible
Gas Line

3" Minimum

Propane/LP
From External
Regulator (11"
W.C. to 14" W.C.
Pressure)

Natural
From Gas Meter
(5" W.C. to
10.5" W.C.
Pressure)

Cap Pipe Tee

Nipple Joint

Sediment Trap

Figure 14 - Gas Connection

* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer. See Accessories, page 30.

INSTALLATION

Continued

WARNING: Use pipe joint sealant that is resistant

to liquid petroleum (LP) gas.

Installation must include an equipment shutoff valve, and plugged 1/8"
NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap
must be upstream from fireplace insert (see Figure 14).

IMPORTANT:

Install equipment shutoff valve in an accessible

location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.

Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.

INSTALLATION

Installing Gas Piping To Fireplace Location (Cont.)

Connecting Fireplace Insert To Gas Supply

Figure 13 - External Regulator with Vent Pointing Down

Propane/LP
Supply
Tank

External
Regulator

Vent Pointing
Down

We recommend that you install a sediment trap in supply line as
shown in Figure 14. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into fireplace insert gas controls. If sediment trap is not
installed or is installed wrong, fireplace may not run properly.

CONNECTING FIREPLACE INSERT TO GAS
SUPPLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not provided)

1.

Remove fireplace insert screen. Lift fireplace insert screen up
and pull out to remove.

2.

Remove screws that attach log base assembly to fireplace in-
sert (see Figure 15). Carefully lift up log base assembly and
remove from fireplace insert (see Figure 15).

Note:

If adding the G8010 series brick liner accessory, install it

now. Follow instructions in G8010 accessory kit.

CAUTION: Do not pick up log base assembly by

burners. This could damage burners. Only handle
base by grates.

3.

Route gas supply line through access opening of fireplace in-
sert (see Figure 15).

Figure 15 - Removing Log Base Assembly From Fireplace Insert

O
F

F

P

IL

OT

O

N

H

I

L

O

Burners

Two Screws

Log Base Assembly

Gas Line
Access

Advertising