Wiring diagrams, Specifications, Vi33nr vi33pr – Desa VI33NR VI33PR User Manual

Page 21

Advertising
background image

111285-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

21

21

WIRING DIAGRAMS

SPECIFICATIONS

WIRING DIAGRAMS

Note

: For proper operation of optional accessories, the wires from

the switch to the control must be connected exactly as shown in
Figures 43 and 44.

AUT

O

OF

F

ON

Thermopile

Figure 43 - Switch Wiring Diagram

Red

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

Blue

Figure 44 - Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.

SPECIFICATIONS

VI33NR

VI33PR

Btu (Variable)

20,000/30,000

20,000/30,000

Type Gas

Natural Gas Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Manifold

3.5" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

14"

Minimum*

5"

11"

* For input adjustment