System set up, Various information during the process, This screen shows the version – SkyRC RS16 180W/16A Balance Charger/Discharger User Manual

Page 17

Advertising
background image

Capacity Cut-Off
ON 5000mAH

Key Beep ON
Buzzer ON

Capacity

Current

Safety Time

2000mAh

2.0A

(2000/2.0=1000)/11.9=84 minutes

3300mAh

3.0A

(3300/3.0=1100)/11.9=92 minutes

1000mAh

1.2A

(1000/1.2=833)/11.9=70 minutes

For example:

This program sets the maximum charge
capacity that will be supplied to the battery
during charge. If the deltapack voltage is not
detected nor the safety timer expired by any
reason, this feature will automatically stop the
process at the selected capacity value.

The beep sounds at every time pressing the
buttons to confirm your action. The beep or
melody sounded at various times during
operation to alert different mode changes.
These audible sounds can be on or off.

Input Power Low
Cut-Off 11.0V

This program monitors the voltage of input
battery. If the voltage drops below the value
you set the operation forcibly terminated to
protect the input battery.

Ext. Temp 0C
Int. Temp 37C

This screen shows the external and internal
temperature.

result by 11.9, set this number as the value for
safety timer setting. If the charger stopped at
this threshold, about 140% of the capacity will
have been fed into the battery.

SYSTEM SET UP

UP DOWN

-

+

UP DOWN

-

+

UP DOWN

UP DOWN

-

+

UP DOWN

UP DOWN

-

+

UP DOWN

UP DOWN

VARIOUS INFORMATION DURING THE PROCESS

VERSION
1.00

LOAD FACTORY SET
ENTER

Press and hold the Start/Enter dial for 3 seconds
to load the factory set.

This screen shows the version.

You can inquire various information on LCD screen during charging or
discharging process. When you rotate the dial counterclockwise, the
screen will display the user’s settings.
And also you can monitor the voltage of individual cell by rotating the
dial clockwise when the individual connection cable is linked to the
Lithium battery being processed.

Ext. Temp 0C
Int. Temp 26C

It comes to the final voltage when the program
ended.

Present input voltage.

This screen shows the internal temperature.

Displayed safety timer is turn on and duration of
time in minutes.

Displayed capacity cut-off function is turn on and
the setting value of capacity.

The battery is connected with balance lead, you
can check voltage of each cell in the battery pack.

VARIOUS INFORMATION DURING THE PROCESS

4.19 4.15 4.18V
0.00 0.00 0.00V

UP DOWN

Advertising