SkyRC Program Box User Manual

Page 2

Advertising
background image

4. Servo Tester

It can check the input voltage, servo travel position and peak current.
The default servo neutral position is 1520us/100Hz and 760us/100Hz. If the testing servo is not
1520us/100Hz and 760us/100Hz, please enter CUSTOM and set the servo neutral
position(range:200-2000us) and frequency(range: 50-200Hz) by yourself.
There are two kinds of mode (Swing Mode and Manual Mode) to make the servo swing and check
the servo travel position.
Swing Mode: it will send out a signal to make the servo swing automatically
Manual Mode: it allows you to change the PPM signal and check the servo's response to the signal.
Connection

4 / 6

V:6.03V F: 96Hz
PPM:1490us

Battery Monitor
PPM Monitor

V:6.01V F: 96Hz
PPM:2075us

V:6.01V F: 96Hz
PPM:1044us

Neutral Pulse Position

Lowest Pulse Position

Highest Pulse Position

ENTER

KV/RPM
Servo Tester

N:1499us
F:100Hz

Set [custom]
Set [1520us]

ENTER

Set [1520us]
Set [760us]

ENTER

Set Swing Mode
Set Manual Mode

W [1499us] 0.00V
M>>1499us Pk0.0A

ENTER

W [1499us]00.00V
100us

Pk0 0A

:

.

W [1499us] 0.00V
M>>1499us Pk0.0A

Set Swing Mode
Set Manual Mode

W [1499us] 0.00V
M>>1499us Pk0.0A

ENTER

* Remark 1

* Remark 2

* Remark 3

Neutral
Pulse Position

Input
Voltage

Peak
Current

Current
Pulse Position

Changing Amplitude
of the Pulse Width

ENTER

ENTER

Manufactured by
SKYRC TECHNOLOGY CO., LTD.
www.skyrc.com

RoHS

7504-0348-01

We guarantee this product to be free of manufacturing and assembly defects for a period of one year
from the time of purchase. The warranty only applies to material or operational defects, which are
present at the time of purchase. During that period, we will repair or replace free of service charge for
products deemed defective due to those causes.
You will be required to produce proof of purchase (invoice or receipt). This warranty is not valid for any
damage or subsequent damage arising as a result of misuse, modification or as a result of failure to
observe the procedures outlined in this manual.

WARRANTY AND SERVICE

5 / 6

6 / 6

When you enter this screen, Press and to choose the right neutral pulse position
of the servo and enter to frequency setting. Press and to choose the right
frequency and enter swing/manual screen.

In the screen, press and to change the amplitude of the pulse width.

In this screen, press and to change the pulse width and check the response of
the servo to different pulse width.

* Remark 1

* Remark 2

* Remark 3

5. Motor KV/RPM Tester

It can check the motor KV, RPM and input voltage.

Connect the Program Box with ESC, receiver, motor, motor sensor cable and battery as the
diagram above, and turn on the ESC and set the pole number (range: 2, 4, 6, 8,...28.) of the
motor by pressing and key.

After you set the motor pole number, move the trigger to get the motor KV and when the trigger is
moved to full throttle, you can read the motor RPM valve from the screen.

PPM Monitor
KV/RPM

ENTER

KV 4000 Pole:2
RPM:33600 8.4V

KV 4000 Pole:6
RPM:33600 8.4V

KV 4000 Pole:6
RPM:33600 8.4V

6. PC Interface - Link ESC to PC

You could use it as SkyLink(SK-600013) to link the ESC with PC, and update the firmware of the
ESC or program the ESC by SkyLink software on PC.

Connect the Program Box as the diagram above, turn on the ESC and do as follows,

ESC Setting
Battery Monitor

简介

USB----PC

USB
Connected to PC!

ENTER

When you see above screen, you could start to program the ESC in PC.

Note: Please click to check whether there is update version of the Program Box.
And if there is, you could click to update your Program Box.

Firmware Update

Update

To

PC

Advertising