4.7 Timing Functions

4 COMPRESSOR

4.7.2 Compressor Release Control

The release control varies the timing behaviour of the compressor during the recovery

period after a gain reduction, when the signal level has reduced from previous levels
above the threshold.

release = minimum

release = quarter-range

release = half-range

The above diagrams show that action of the release control from minimum to half range
(maximum range is too long to show successfully on this diagram).

www.sonnox.com