Pattern programming, High/low jumper, Led indicator – Star Headlight & Lantern 400B User Manual

Page 3: The pattern select jumper is stored on pins 1 & 2

Advertising
background image

PATTERN SELECT

JUMPERS

DIAGNOSTIC

LED

S8070-159-13

RED LEAD w/FEMALE TERMINAL

(FOR RED WIRE)

MALE TERMINAL

(FOR BLACK WIRE)

3 2 1

3 2 1

MALE TERMINAL

(FOR PURPLE WIRE)

HIGH/LOW SELECT

JUMPERS

RED LEAD w/FEMALE TERMINAL

(FOR RED WIRE)

MALE TERMINAL

(FOR BLACK WIRE)

S8070-159-14

MALE TERMINAL

(FOR PURPLE WIRE)

3 2 1

PATTERN SELECT

JUMPERS

3 2 1

DIAGNOSTIC

LED

HIGH/LOW SELECT

JUMPERS











Pattern Programming

The circuits now found in these lights have a jumper on them allowing the end user to
select the desired flash pattern (singleflash, doubleflash, or quadflash). If you wish to
change the pattern, activate the light and follow the instructions below.

1. The Pattern Select Jumper is stored on pins 1 & 2.

2. To change the pattern, remove the

jumper from pins

1 & 2, momentarily place it over pins 2 & 3,

then remove it. The pattern should advance
to the next.

3. Continue to touch and release the jumper to

pins 2 & 3 to cycle through the patterns:

singleflash

à doubleflashà quadflash

4. Once you have selected a pattern,

replace the jumper on pins 1 & 2.

Please Note: Some circuits may have only two pins.

For those circuits, store the jumper on
one of the pins, and use the jumper on
the two pins for programming.

High/Low Jumper

Mag mount models will come with a
jumper that automatically defaults the light
to High Power. To only run on Low
Power, move the High/Low Select Jumper
from pins 1 & 2 to pins 2 & 3.

LED Indicator

These lights also have an LED
Diagnostic Indicator
.
The LED
indicator is designed to flash when the
strobe tube should be flashing. If a strobe
light is not working, troubleshooting
becomes easy with this new LED. Simply
examine the circuit when power is applied
to it. If the strobe tube is not flashing, but
the LED is flashing, you have a bad strobe
tube. If the LED is not flashing, the circuit
is either not receiving the proper voltage,
or the circuit has failed.

SP3860-2H SWITCH PANEL (REAR VIEW)

OFF

SW1

SW2

LOW

2

1

3

HIGH

2

1

3

ON

RED

PURPLE

BLACK

WARNING

LIGHT

PURPLE

RED

GOOD

CHASSIS
GROUND

GOOD

CHASSIS
GROUND

BLACK

10 AMP

FUSE

CONNECT RED

FUSED LEAD TO

+12 VDC

A t w o-switch switch-panel is

required to utilize the High/Low

power option. Make your

connections as illustrated above.