Table 1: motor start controls, Activity led out signal, Spindle sync – StorCase Technology DX100-SWC User Manual

Page 2: Scsi id select

Advertising
background image

D89-0000-0069 Rev. B01

StorCase Technology, Inc.

DX100-SWC

Table 1: Motor Start Controls

Activity LED Out Signal

The Activity LED Out Signal, provided by the drive, is intended to support a drive activity LED.

This signal is designed to pull down the cathode of the activity LED indicator during periods

while the drive is forming SCSI operations.

Spindle SYNC

The Spindle SYNC signal is provided for spindle synchronization between multiple drives.

Synchronized drives should be of the same or equivalent model types. (Synchronization

protocol and the electronic requirements for the SYNC signal are defined within the drive

specifications. Spindle synchronization is managed by the SCSI command set).

The Single-Connect Adapter Board provides

2 sets of Spindle SYNC pins. To implement

this option, a jumper wire must be run from

the SYNC pin on the Adapter Board to a SYNC

pin on another drive or Adapter Board. This

signal may be jumpered in a daisy-chain con-

figuration for up to 15 drives.

SCSI ID Select

Each device on the SCSI bus must have a

unique SCSI ID number. The SCSI ID Select

pins allow the selection of an appropriate

SCSI ID (0-15 for 16-bit connections).

Jumpers on the Single-Connect Adapter Board are factory-installed on the Enable Termination

Power (TPR) pins, and on all of the SCSI ID Select (ID0-ID3) pins. These jumpers may be

reconfigured as required. Refer to the following information for pin descriptions.

Advertising