INSTALLATION

Continued

INSTALLATION

Connecting Equipment shutoff Valve To Heater Control (Cont.)

Checking Gas Connections

2.

Route flexible gas line, included, from fireplace control to
equipment shutoff valve through side or rear access holes in
outer casing.

3.

Apply pipe joint sealant lightly to male threads of gas connec-
tor attached to flexible gas line/equipment shutoff valve (see
Figure 32).

Figure 32 - Attaching Flexible Gas Line to Equipment Shutoff
Valve

Flexible Gas Line
from Fireplace
Gas Regulator
Provided With
Fireplace

To Gas Regulator (Thermostat-
Controlled Models) or Control
Valve (Remote-Ready Models)

Equipment
Shutoff Valve

PROPANE/LP
To External
Regulator

NATURAL
To Gas Supply

WARNING: Test all gas piping and connections

for leaks after installing or servicing. Correct all
leaks at once.

WARNING: Never use an open flame to check for

a leak. Apply a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.

CAUTION: Make sure external regulator has been

installed between propane/LP supply and fireplace.
See guidelines under

Connecting to Gas Supply,

pages 17 and 18.

Pressure Testing gas Supply Piping system

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.

Disconnect appliance with its appliance main gas valve (control
valve) and equipment shutoff valve from gas supply piping sys-
tem. Pressures in excess of 1/2 psig will damage heater regulator.

2.

Cap off open end of gas pipe where equipment shutoff valve
was connected.

3.

Pressurize supply piping system by either opening propane/LP sup-
ply tank valve for propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or using compressed air.

4.

Check all joints of gas supply piping system. Apply noncorrosive
leak detection fluid to all joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Reconnect fireplace and equipment shutoff valve to gas sup-
ply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see Figure 33).

2.

Pressurize supply piping system by either opening propane/LP sup-
ply tank valve for propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or using compressed air.

CHECKING GAS CONNECTIONS

Figure 33 - Equipment Shutoff Valve

ON

POSITION

OFF

POSITION

Open

Closed

Equipment
Shutoff Valve

CAUTION: Avoid damage to regulator. Hold gas

regulator with wrench when connecting it to gas
piping and/or fittings (Thermostat-Controlled Mod-
els Only).

CAUTION: Avoid damage to gas control. Hold gas

control with wrench when connecting it to gas piping
and/or fittings (Remote-Ready Models Only).

4.

Check all gas connections for leaks. See Checking Gas Con-
nections
.

5.

Replace branch support back into fireplace. Feed flexible gas
line into fireplace base area while replacing branch support. Make
sure the entire flexible gas line is in fireplace base area. Reat-
tach branch support to fireplace with screws removed in step 1.