I n g – DeLonghi PAC-A130HPE User Manual

Page 13

Advertising
background image

16

Tr o u b l e s h o o t i n g

PROBLEM CAUSE

REMEDY

The air conditio-
ning unit does not
start

.

•

No electricity.

•

It is not plugged into the outlet.

•

The safety device of the plug has tripped.

•

The internal safety device has tripped.

•

Restore electricity.

•

Plug into the outlet.

•

Reset the safety plug.

•

Wait 30 minutes, if the pro-
blem persists, contact your
service center.

The air conditio-
ning unit works for
a short time only.

•

The air exhaust hose has a constriction.

•

The air exhaust hose is blocked.

•

There are tight bends in the air exhaust
hose.

•

Position the exhaust hose
correctly.

•

Check there are no obsta-
cles Obstructing air dischar-
ge.

•

Eliminate the tight bends.

The air conditioner
works, but does
not cool the room.

•

Window open.

•

There are heat sources in the room
(lamps, etc.).

•

The exhaust hose is detached.

•

Air filters clogged

.

•

Close the window.

•

Eliminate the heat source.

•

Connect the exhaust hose.

•

Clean or replace the filters.

•

Clean or replace the filter.

Bad odor in the
room.

•

The filter is clogged.

The air conditioner
does not operate
for about 3 minu-
tes after turning it
on

.

•

The internal compressor safety device
prevents the appliance from being restar-
ted until three minutes have elapsed
since it was last turned off.

•

Wait. This delay is part of nor-
mal operation.

/

PF/ appears

on the display.

•

The appliance has a self diagnosis system
to identify a number of malfunctions.

•

See the self-diagnosis chap-
ter.

NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS,
WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the
unit has been on its side, oil needs to return to the compressor to ensure proper function. With-
out allowing the unit this time (6-24 hours) The unit may function for only a short time, and then
the compressor will break down from lack of oil

).

TROUBLESHOOTING

i n g

The unit will not
heat

•

The unit takes several minutes to produce
warm air

•

Wait. This delay is part of
normal operation.

Advertising