Cooling performance with evaporator coils, 2ac13 split system air conditioner – Ducane (HVAC) 2AC13 User Manual

Page 3

Advertising
background image

2AC13 Split System Air Conditioner

13

** = B, L, BC, LC
* = B, L

Cooling Performance with Evaporator Coils

Outdoor

Model

Indoor Model

SEER

EER

Rated

ARI

Capacity

1

Rated

Sensible

Capacity

CFM

Refrigerant

Connection

Refrigerant

Line Size

Indoor

Metering

Device

Piston or Field

Installed TXV

Factory

Installed TXV

Outdoor

Indoor

Suction

Liquid

Req'd

Indoor

2

Orifice

Optional

Field

Installed

Orifice

Suction

Liquid

Suction

Liquid

E(C,M,U)1P18N(A,B)

E(C,M,U)2T18N(A,B)

13.00 11.00

17,000

12,200

550

3/4

3/8

3/4 3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P19NA

E(C,M,U)2T19NA

13.00 11.50

17,000

12,200

550

3/4

3/8

3/4 3/8

3/4

3/8

.053

A2TXV01

E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.50

17,000

12,200

550

3/4

3/8

3/4 3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P24N(A,B)

E(C,M,U)2T24N(A,B)

13.00 11.50

17,000

12,200

550

3/4

3/8

3/4 3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P19NA

E(C,M,U)2T19NA

13.00 11.00

22,800

17,100

750

3/4

3/8

3/4 3/8

3/4

3/8

.062

A2TXV01

E(C,H,M,U)1P23N(A,B)

E(C,H,M,U)2T23N(A,B)

13.00 11.00

23,200

17,400

750

3/4

3/8

3/4 3/8

3/4

3/8

.062

A2TXV01

E(C,M,U)1P24N(A,B)

E(C,M,U)2T24N(A,B)

13.00 11.00

23,000

17,300

750

3/4

3/8

3/4 3/8

3/4

3/8

.062

A2TXV01

E(C,H,M,U)1P29NA

E(C,H,M,U)2T29NA

13.00 11.50

23,000

17,300

750

3/4

3/8

3/4 3/8

3/4

3/8

.062

A2TXV01

E(C,H,M,U)1P23N(A,B)

E(C,H,M,U)2T23N(A,B)

13.00 11.00

27,800

20,900

900

3/4

3/8

3/4 3/8

3/4

3/8

.070

A2TXV01

E(C,H,M,U)1P29NA

E(C,H,M,U)2T29NA

13.00 11.00

28,600

21,500

900

3/4

3/8

3/4 3/8

3/4

3/8

.070

A2TXV01

E(C,M,U)1P30N(A,B,C)

E(C,M,U)2T30N(A,B,C)

13.00 11.00

28,200

21,200

900

3/4

3/8

3/4 3/8

3/4

3/8

.070

A2TXV01

E(C,H,M,U)1P36N(A,B,C)

E(C,H,M,U)2T36N(A,B,C)

13.00 11.00

29,000

21,800

900

3/4

3/8

3/4 3/8

3/4

3/8

.070

A2TXV01

E(C,H,M,U)1P29NA

E(C,H,M,U)2T29NA

13.00 10.50

34,600

26,600

1060 3/4

3/8

3/4 3/8

3/4

3/8

.076

A2TXV01

E(C,H,M,U)1P36N(A,B,C)

E(C,H,M,U)2T36N(A,B,C)

13.00 11.00

34,600

26,600

1060 3/4

3/8

3/4 3/8

3/4

3/8

.076

A2TXV01

E(C,H,M,U)1P43NB

E(C,H,M,U)2T43NBC

13.00 11.00

35,200

27,100

1060 3/4

3/8

7/8 3/8

7/8

3/8

.076

A2TXV01

E(C,H,M,U)1P43NB

E(C,H,M,U)2T43NB

13.00 11.50

40,000

28,000

1250 7/8

3/8

7/8 3/8

7/8

3/8

.080

A2TXV02

E(C,M,U)1P48N(B,C)

E(C,M,U)2T48N(B,C)

13.00 11.00

39,000

27,200

1250 7/8

3/8

7/8 3/8

7/8

3/8

.080

A2TXV02

E(C,H,U)1P49NC

E(C,H,U)2T49NC

13.00 11.00

40,000

28.000

1250 7/8

3/8

7/8 3/8

7/8

3/8

.080

A2TXV02

E(C,H,M,U)1P43NB

E(C,H,M,U)2T43NB

13.00 11.50

45,000

32,000

1600 7/8

3/8

7/8 3/8

7/8

3/8

.088

A2TXV02

E(C,M,U)1P48N(B,C)

E(C,M,U)2T48N(B,C)

13.00 12.00

45,000

32,000

1600 7/8

3/8

7/8 3/8

7/8

3/8

.088

A2TXV02

E(C,H,U)1P49NC

E(C,H,U)2T49NC

13.00 11.50

46,000

32,600

1600 7/8

3/8

7/8 3/8

7/8

3/8

.088

A2TXV02

E(C,M,U)1P50NC

E(C,M,U)2T50NC

13.00 11.50

45,000

32,000

1600 7/8

3/8

7/8 3/8

7/8

3/8

.088

A2TXV02

E(C,U)1P60ND

E(C,U)2T60ND

13.00 11.50

45,000

32,000

1600 7/8

3/8

7/8 3/8

7/8

3/8

.088

A2TXV02

E(C,H,U)1P62NC

E(C,H,U)2T62NC

13.00 12.00

45,500

32,300

1600 7/8

3/8

7/8 3/8

7/8

3/8

.088

A2TXV02

E(C,H,U)1P62ND

E(C,H,U)2T62ND

13.00 12.00

45,500

32,300

1600 7/8

3/8

7/8 3/8

7/8

3/8

.088

A2TXV02

E(C,H,U)1P49NC

E(C,H,U)2T49NC

13.00 11.00

53,000

38,600

1800 7/8

3/8

7/8 3/8 1-1/8 3/8

.098

A2TXV02

EH1P49ND

---

13.00 11.00

53,000

38,600

1800 7/8

3/8

7/8 3/8 1-1/8 3/8

.098

A2TXV02

E(C,H,U)1P62NC

E(C,H,U)2T62NC

13.00 11.50

54,000

39,400

1800 7/8

3/8

7/8 3/8 1-1/8 3/8

.098

A2TXV02

E(C,H,U)1P62ND

E(C,H,U)2T62ND

13.00 11.00

53,000

38,600

1800 7/8

3/8

7/8 3/8 1-1/8 3/8

.098

A2TXV02

2AC13**18P

2AC13**24P

2AC13**30P

2AC13**36P

2AC13*42P

2AC13*48P

2AC13*60P

1

Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.

2

Required to achieve ARI rating.

A blower time delay is required to achieve ARI rating.

Advertising