13

Cooling Performance with Air Handlers and Furnaces (18)

Indoor Model

Variable

Speed

Furnace

SEER

EER

Rated

ARI

Capacity

1

Rated

Sensible

Capacity

CFM

Refrigerant

Connection

Refrigerant

Line Size

Indoor

Metering

Device

Piston or Field

Installed TXV

Factory

Installed TXV

Outdoor

Indoor

Suction

Liquid

Req'd

Indoor

2

Orifice

Optional

Field

Installed

Orifice

Suction

Liquid

Suction

Liquid

RBCS2M18C****P

RBCS2M18C****T

---

13.00

12.00

17,900

12,900

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

RBCS2M24V****P

---

---

14.00

12.50

18,000

13,000

550

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P18NA

E(C,M,U)2T18NA

CMPEV050

14.00

12.00

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P18NA

E(C,M,U)2T18NA

CMPEV075

14.00

12.00

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P18NA

E(C,M,U)2T18NA

MPGAV050

14.00

12.00

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P18NA

E(C,M,U)2T18NA

MPGAV075

14.00

12.00

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P19NA

E(C,M,U)2T19NA

CMPEV050

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P19NA

E(C,M,U)2T19NA

CMEV075

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P19NA

E(C,M,U)2T19NA

MPGAV050

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,H,M,U)1P19NA

E(C,H,M,U)2T19A

MPGAV075

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,H,M,U)1P23NA

E(C,H,M,U)2T23NA

CMPEV050

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,H,M,U)1P23NA

E(C,H,M,U)2T23NA

CMPEV075

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,H,M,U)1P23NA

E(C,H,M,U)2T23NA

MPGAV050

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,H,M,U)1P23NA

E(C,H,M,U)2T23NA

MPGAV075

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P24NA

E(C,M,U)2T24NA

CMPEV050

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P24NA

E(C,M,U)2T24NA

CMPEV075

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P24NA

E(C,M,U)2T24NA

MPGAV050

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

E(C,M,U)1P24NA

E(C,M,U)2T24NA

MPGAV075

14.00

12.50

17,300

12,500

600

3/4

3/8

3/4

3/8

3/4

3/8

.053

A2TXV01

Outdoor

Model

2AC13**18P

** = B, L, BC, LC
* = B, L

1

Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.

2

Required to achieve ARI rating.

A blower time delay is required to achieve ARI rating.