Simple circuit for for domestic central heating
boiler with gravity fed hot water supply

This diagram is correct for mains operated
systems� The link wire L-3 must be fitted by the
installer�

TOWERCHRON QM1 is ideally suited for controlling combination boilers� The following basic circuit
diagrams apply for the range indicated�

Room stat conversation chart

Wiring installation instruction (QM1)

N

L

D

S

neutral

room stat

D = demand
S = satisfy

neutral

220/240V
50 Hz AC
main supply

boiler

pump

1

2

3

4

TOWER SS

E

E

N

4

C
O

M

1

D

E

M

2

S
A
T

TOWER SSTRS

E 4 1 3

ACL TS 142

E 4 1 2

DRAYTON RTE

E 4 1 2 3

HONEYWELL T 6160B

2 1 3 4

LANDIS&GYR RAD 5

4 6 2

SWITCHMASTER SRT2 5

1 3 2

SUNVIC TLX2259

E 4 3 1