Ubiquiti Networks airFibe24 User Manual

Page 14

Advertising
background image

11

Chapter 2: Installation

airFiber

®

AF24 User Guide

Ubiquiti Networks, Inc.

3.

Master

Aim the Master at the Slave. If necessary, adjust

the Master’s position on the pole:

a. Loosen the Hex Nuts.
b. Adjust the Pole Mount Bracket and Pole Clamps.
c. Tighten the Hex Nuts.

Hex Nuts

Master

4.

Slave

Aim the Slave at the Master to achieve the

strongest received signal level on the Slave’s numeric
LED Display, which is located next to the Config port. If
necessary, adjust the Slave’s position on the pole.

Slave RF Power (-dBm)

Note:

Values on the LED Display are displayed

in negative (-) dBm. For example, 61 represents
a received signal level of -61 dBm. Lower values
indicate stronger received signal levels.

5.

Master

Adjust the azimuth and elevation of the Master

until the strongest received signal level is displayed on
the LED Display of the Master.

a. Sweep the Azimuth (AZ) Adjustment Bolt of the Master

through its adjustment range.

Master
Azimuth (AZ)
Adjustment Bolt

b. Sweep the Elevation (EL) Adjustment Bolt of the Master

through its adjustment range.

Master
Elevation (EL)
Adjustment Bolt

Master RF Power (-dBm)

Note:

: If the LED Display indicates an overload

condition , see ”RX Gain” on page 24
for more details about RX Gain and overload
condition.

Advertising