CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace

directly to the propane/LP supply. This fireplace
requires an external regulator (not supplied). Install
the external regulator between the fireplace and pro-
pane/LP supply.

For propane/LP units, the installer must supply an external regula-
tor. The external regulator will reduce incoming gas pressure. You
must reduce incoming gas pressure to between 11 and 14 inches of
water. If you do not reduce incoming gas pressure, fireplace regu-
lator damage could occur. Install external regulator with the vent
pointing down as shown in Figure 20, page 13. Pointing the vent
down protects it from freezing rain or sleet.

WARNING: This appliance requires a 1/2" NPT

(National Pipe Thread) inlet connection to the pres-
sure regulator.

INSTALLATION

Continued

Figure 18 - Installing Blower Bracket Assembly

Figure 19 - Wiring Diagram For Fan Accessory Built-In Installation

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Blower Bracket
Assembly

Screw

Wire
Harness

Power Cord

Blower
Control
Shield

Shield
Cover

Wire
Harness

Switch
Plate

Switch

Clamp Connector
(not included)

Outlet
Receptacle

Blue

Red

Strain
Relief

WARNING: Never connect natural gas fireplace to

private (non-utility) gas wells. This gas is commonly
known as wellhead gas.

INSTALLATION

Installing Blower Assembly - GA3450T (Cont.)
Connecting to Gas Supply

Installation Items

Before installing fireplace, make sure you have the items listed
below.

• external regulator - propane/LP only (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• sediment trap

• tee joint

• pipe wrench

• test gauge connection*

* A CSA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. Purchase
the optional CSA design-certified equipment shutoff valve from
your dealer. See Accessories, page 29.

Note:

If desired, purchase a four-sided trim kit for built-in

installations. See Accessories, page 29.

5.

Test to make sure the blower is working properly.

6.

Reinstall hood assembly (see pages 9 and 10) and close lower
louver door.

7.

Place log set back on the unit.

Advertising