8) key-cv outputs 1-4 (1v/oct), 11) reset output – Vermona qMI - quad MIDI Interface User Manual

Page 11

Advertising
background image

(8) Key-CV outputs 1-4 (1V/OCT)

The connectors output control voltages that equal the note pitches
received at the MIDI-input. Key-CV voltage ranges from 0 to 5 volts fol-
lowing a conversion scheme of 1 volt per octave. For use, please refer to
section "Connecting the Gate- and Key-CV-Outputs" on page 13.

(9) / (10) Control voltage outputs 1-4 (CV1 / CV2)

These connectors output continuously variable control voltages ranging
between 0 and 5 volts. These control-voltages derive from different
assignable MIDI-controllers. For use, please refer to section "Control
voltage outputs (CV1 / CV2)
" on page 17.

(11) RESET output

The reset-output interprets the status of a MIDI-sequencer. With the
reception of a stop-command, a permanent voltage of +10 volts is
being output. With the reception of MIDI-start or continue-command,
the output's voltage is set to 0 volt. For use, please refer to section
"Reset-output (RESET)" on page 19.

(12) Clock division outputs (1/4, 1/8, 1/16, 1/8T)

These four connectors output clock-signals deriving from a received
MIDI-clock of a connected sequencer. Each output carries a different
clock divided signal. Clock impulses are sent with 10 volts and positive
polarity. For use, please refer to section "Clock division outputs (1/4,
1/8, 1/16, 1/8T)
" on page 19.

Owner's Manual - VERMONA*modular qMI - quad MIDI Interface

- 11 -

Advertising